Pulmonary vein isolation in a patient with atrial fibrillation and a filter in the inferior vena cava
نویسندگان
چکیده
A 60-year-old man with a 1-year history of highly symptomatic drug-resistant paroxysmal atrial fibrillation (AF) was admitted for pulmonary vein isolation (PVI). In 1984 the patient had hemorrhagic stroke of the left hemisphere with right-sided hemiparesis that was complicated with pulmonary embolism. Therefore the patient was treated with surgical implantation of a prototype filter to the vena cava inferior (VCI). His medical history included hypertension, diabetes mellitus, transient ischemic attack and epilepsy. Using the transfemoral approach under fluoroscopic guidance, the diagnostic catheter was placed in the coronary sinus. Crossing the filter with the long guidewire of the transseptal sheath (8.5 Fr SL0, St Jude Medical, Minnetonka, MN, USA) turned out to be impossible. To overcome this problem we advanced the transseptal sheath over the guidewire next to the filter and only then managed to pass the guidewire (and then the sheath) by the filter (Figure 1). Double transseptal puncture was performed successfully. Using the CARTO system, Lasso diagnostic catheter (Biosense Webster, Diamond Bar, Ca, USA) and Navistar ThermoCool Smarttouch ablation catheter (Biosense Webster, Diamond Bar, Ca, USA), successful PVI was performed. The overall procedure time was 215 min. Total fluoroscopy exposure was 31 min and 53 s (6141.9 cGy · cm2). During 12 months of follow-up there was no AF (24-hour ECG monitoring at 3, 6, 9, and 12 months after ablation). The VCI filters are inserted for prevention of pulmonary embolus from lower extremity deep vein thrombosis [1]. Presence of a VCI filter has traditionally been considered a relative contraindication for catheterization from the femoral vein [2]. To our knowledge, this is the first case of successful PVI in a patient with AF and presence of an unknown type of filter in the VCI. The decision to perform the catheter procedure largely depends on the filter type in the VCI. Over the past decade, there has been a gradual evolution of VCI filters [3]. Limited data are available on complicating the standard procedure catheterization across the filter in the VCI [4]. During crossing the filter we used continuous fluoroscopy to reduce the risk of adverse events. It was necessary to bring the sheath close to the filter. The solution was to use a straight guidewire for passage of the filter. All maneuvers were performed without filter dislodgment. The PVI is possible but much more complicated in patients with a filter in the VCI.
منابع مشابه
Radiofrequency wire–facilitated transseptal access using a superior approach for atrial fibrillation ablation in a patient with inferior vena cava obstruction
Introduction The standard approach to contemporary atrial fibrillation ablation involves obtaining trans-septal access to the left atrium from an inferior approach using percutaneous femoral venous access. Rarely, access to the heart from the inferior approach is not possible due to vascular anomalies or venous occlusions. In these unusual cases, a superior approach to pulmonary vein isolation ...
متن کاملInnappropriate Sinus Tachycardia After Superior Vena Cava Isolation In Addition To Pulmonary Veins Isolatin Of Paroxysmal Atrial Fibrillation Cryoballoon Ablation.
We report a case of persistent inappropriate sinus tachycardia (IST) after pulmonary vein and superior vena cava (SVC) isolation with cryoballoon ablation for paroxysmal atrial fibrillation (PAF). After the cryoballoon ablation (CBA) procedure, the patient presented with sinus tachycardia of 105 beats/minute. The patient was successfully treated with metoprolol and ivabradine therapy.
متن کاملThromboembolic complications after an ankle joint open fracture in a patient with a history of deep vein thrombosis in the lower limbs
A 55-year-old patient was admitted to the Department of Orthopedics due to an open fracture in the right ankle joint. On the seventh day of hospitalization the patient experienced a transient ischemic attack. During the next day, dyspnea, chest pain and a 'rider' type pulmonary embolism in the pulmonary trunk occluding both pulmonary arteries and its branches were diagnosed. The patient was tra...
متن کاملAtrial fibrillation ablation with persistent left superior vena cava detected during intracardiac echocardiography
Introduction Atrial fibrillation ablation is an increasingly frequent procedure performed in the electrophysiology laboratory. Pulmonary vein foci account for more than 90% of triggers for atrial fibrillation, most commonly treated with complete pulmonary vein isolation most of the time. Non–pulmonary vein triggers are the drivers of atrial fibrillation in a subgroup of patients. This patient h...
متن کاملFocal Atrial Fibrillation from the Superior Vena Cava.
We report the case of a 66 year-old male who underwent catheter ablation for drug-refractory paroxysmal atrial fibrillation (AF) at our institution. Radiofrequency catheter ablation was performed using a three-dimensional electroanatomical mapping system. During ablation of the pulmonary veins (PV), right atrial ectopics were noted to repeatedly trigger AF and atrial tachycardia (AT). After PV ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2017