Separation and control of the elution order of N-t-butyloxycarbonyl amino acids D/L isomers by reversed-phase HPLC using cyclodextrins as chiral selectors for the mobile phase.
نویسندگان
چکیده
The enantiomeric resolution of N-t-butyloxycarbonyl (N-t-Boc) amino acids D/L isomers by reversed-phase HPLC was investigated using cyclodextrins (CD's) as chiral selectors for the mobile phase. The use of a low pH (pH<4) for the mobile phase enabled the enantioseparation of N-t-Boc amino acids. The opposite elution order of D/L isomers was observed when hydroxypropyl-derivatized beta-CD was used instead of native beta-CD. A computer simulation of the enantioseparation showed that the ratio of the retention factors of the chiral selector and the sample determined the elution order and the resolution. When the retention factor of the chiral selector is smaller than that of the sample, an isomer having larger complex formation constant eluted faster. However, when the chiral selector had a larger retention factor than the sample, an opposite elution order of the isomers was obtained. The large difference in the retention factors between the chiral selector and the sample led to good enantiomeric separation.
منابع مشابه
Development of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملDetermination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction
A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...
متن کاملPerformance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملChiral recognition mechanisms of four β-blockers by HPLC with Amylose Chiral Stationary Phase
The high performance liquid chromatography (HPLC) enantioseparation of four β-blocking agents metoprolol, bisoprolol, propranolol and atenolol was performed on amylose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase using n-hexane-ethanol-diethylamine (DEA) as the mobile phase and related chiral recognition mechanisms were discussed. Enantiomeric separation of the fourβ-blockers was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2002