EVect of spirometer temperature on FEV1 in a longitudinal epidemiological study
نویسندگان
چکیده
Objectives—To assess the magnitude of error in pulmonary function measurements introduced by variation in spirometer temperature under field conditions. In a large scale epidemiological study of school children, the influence was investigated of spirometer temperature on forced expiratory volume in 1 second (FEV1) measured with dry rolling seal volumetric spirometers and conventional body temperature, pressure, and saturation (BTPS) corrections. Methods—Linear regression analyses were performed on data from 995 testretest pairs on 851 diVerent children, with 1–110 days between test and retest, and spirometer temperature diVerences between −13°C and +9°C. Results—After adjusting for eVects of growth (test-retest intervals) and circadian variation (changes in times of testing), differences in standard BTPS corrected FEV1 showed significant (p<0.05) dependence on diVerences in spirometer temperature between tests (−0.24%/°C). Conclusions—When spirometer temperatures vary widely, standard BTPS correction does not fully adjust for gas contraction. To improve accuracy of volume measurements in epidemiological studies, additional correction for variation in spirometer temperature should be considered. (Occup Environ Med 1999;56:718–720)
منابع مشابه
Effect of spirometer temperature on FEV1 in a longitudinal epidemiological study.
OBJECTIVES To assess the magnitude of error in pulmonary function measurements introduced by variation in spirometer temperature under field conditions. In a large scale epidemiological study of school children, the influence was investigated of spirometer temperature on forced expiratory volume in 1 second (FEV1) measured with dry rolling seal volumetric spirometers and conventional body tempe...
متن کاملAgreement between spirometers: a challenge in the follow-up of patients and populations?
BACKGROUND Long-term cohort studies and lung function laboratories are confronted with the need for replacement of spirometers. Lack of agreement between spirometers might affect the longitudinal comparison of data, notably when replacing conventional by portable spirometers. OBJECTIVES To compare the handheld EasyOne (EO) with the conventional SensorMedics (SM) spirometer, and to analyze the...
متن کاملA comparison of the Jones and Stead-Wells spirometers.
A comparison was made between the noncounterweighted Jones and Stead-Wells spirometers, and "conversion factors" were determined for the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). A cross-sectional study produced a high correlation between the instruments for these two measurements, yielding quadratic and linear regression equations ("conversion factors")...
متن کاملAnalysis of changes in pulmonary functions at rest following humidity changes
[Purpose] The purpose of this study was to compare the effect of humidity changes on the values of pulmonary function at rest. [Subjects and Methods] This study was conducted with 30 young adults (9 males, 21 females; mean age 19.4 years). Participants' mean height was 165.1 cm, and their mean weight was 60.2 kg. The experimental setting was a laboratory in which temperature was fixed at 25 °C....
متن کاملValidation of the portable Air-Smart Spirometer
BACKGROUND The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet. METHODS In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air S...