A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian
نویسندگان
چکیده
During toric intraocular lens (IOL) implantation, surgeons must take particular care to ensure that inaccurate preoperative measurement and intraoperative misalignment do not cause unexpected postoperative residual astigmatism. This retrospective, comparative case series study aimed to analyze the rotational deviation, or cyclotorsion, of three corneal marking methods: VERION digital marker (VDM; reference), horizontal slit beam marking (HSBM), and subjective direct visual marking (SDVM) on the table (using a bevel knife tip). Subjects included 81 eyes of 61 patients (mean age: 65.70±13.14 years; range: 32-91 years) undergoing scheduled cataract surgery. A preoperative reference image was taken of each eye. Subsequently, a slit lamp with the light beam turned to the horizontal meridian was used to align the seated patient's head, and two reference marks were placed at the 3- and 9-o'clock positions of the corneal limbus using a 27-gauge needle and marking pen (HSBM). Upon transfer to the surgical table, the VDM was used to display a real-time dial scale on the patient's eye, with the entrance of the temporal clear corneal incision (CCI) at 0° (horizontal meridian). Simultaneously, a bevel knife tip was used to create a marker based on the surgeon's visual determination of the temporal 0° point (SDVM). We used the VDM to quantitatively evaluate the accuracy of axis alignment via deviation from the horizontal reference meridian. Compared with the reference meridian, the SDVM (-3.46°±7.32°, range: -18° to 13°) exhibited greater average relative cyclotorsion versus the HSBM (0.41°±4.92°, range: -10° to 10°). Furthermore, the mean average misalignment was significantly less in the HSBM group versus the SDVM group (t=4.179, P<0.001). The VDM is likely a reliable marking method, similar to the HSBM. In contrast, the SDVM is not entirely reliable. The VDM usage may prevent inaccurate preoperative manual marking during toric IOL implantation.
منابع مشابه
Surgically induced astigmatism after phacoemulsification with and without correction for posture-related ocular cyclotorsion: randomized controlled study.
PURPOSE To report the impact of posture-related ocular cyclotorsion on one surgeon's surgically induced astigmatism (SIA) results and the variance in SIA. SETTING Institute of Eye Surgery, Whitfield Clinic, Waterford, Ireland. METHODS This prospective randomized controlled study included eyes that had phacoemulsification with intraocular lens implantation. Eyes were randomly assigned to hav...
متن کاملاندازهگیری قطر افقی قرنیه نوزادان ایرانی
Introduction : Horizontal corneal diameter is one of the diagnostic factors in some ophthalmic diseases. At present American Newborn horizontal corneal diameter is considered as our normal value in Iranian ones, while it may be quite different in Iranian newborns. Early diagnosis is critical in some ophthalmic diseases such as congenital glaucoma and awareness of normal corneal diameter is es...
متن کاملEffects of Pterygium Excision on Corneal Curvatures
Objective: To determine the difference in mean corneal curvatures before and after pterygium excision, by using automated refraction and keratometry. Methodology: This quasi-experimental study was conducted at Eye Unit-I, Bahawal Victoria Hospital, Bahawalpur, from March 2010 to August 2010. Thirty patients with primary pterygium were analyzed before and after pterygium surgery for corneal curv...
متن کاملTopographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure.
PURPOSE To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT). METHODS Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of...
متن کاملProjecting Cultural Identity through Metadiscourse Marking; A Comparison of Persian and English Research Articles
Writing projects are socially-situated identities. The rhetorically-loaded aspects of writing, like metadiscourse marking, are more prone to carry such identities. Through analyzing metadiscourse strategies employment in Persian and English (as the lingua franca of academic discourse community) research articles, this study makes an attempt to find out whether Persian native writers take on the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2017