Exposure to trichloramine and respiratory symptoms in indoor swimming pool workers.

نویسندگان

  • J H Jacobs
  • S Spaan
  • G B G J van Rooy
  • C Meliefste
  • V A C Zaat
  • J M Rooyackers
  • D Heederik
چکیده

The association between swimming pool characteristics and activities of employees and respiratory symptoms in employees was studied. Trichloramine levels were measured to evaluate relationships with pool characteristics and to estimate long-term exposure levels. Questionnaires were available from 624 pool workers and 38 swimming facilities. Chloramine levels were measured by area sampling over 2-h periods and analysed using ion chromatography. Work-related and general respiratory symptoms, and symptoms indicative of atopy and bronchial hyperresponsiveness were considered. Respiratory symptom prevalence among pool workers was compared with symptoms in a Dutch population sample. Chloramine levels were modelled with regression analysis. This model was used to estimate long-term average chloramine levels for each pool studied. Employees with higher exposure reported upper respiratory symptoms with greater frequency. Upper respiratory symptoms were statistically significantly associated with cumulative chloramine levels (odds ratio (OR) >1.4 for hoarseness, lost voice, sinusitis). General respiratory symptoms were significantly elevated compared with a Dutch population sample (OR ranged 1.4-7.2). An excess risk for respiratory symptoms indicative of asthma was observed in swimming pool employees. Aggravation of existing respiratory disease or interactions between irritants and allergen exposures are the most likely explanations for the observed associations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airway irritation among indoor swimming pool personnel: trichloramine exposure, exhaled NO and protein profiling of nasal lavage fluids.

PURPOSE Occurrence of airway irritation among indoor swimming pool personnel was investigated. The aims of this study were to assess trichloramine exposure levels and exhaled nitric oxide in relation to the prevalence of airway symptoms in swimming pool facilities and to determine protein effects in the upper respiratory tract. METHODS The presence of airway symptoms related to work was exami...

متن کامل

Lung function in volunteers before and after exposure to trichloramine in indoor pool environments and asthma in a cohort of pool workers

OBJECTIVES Exposure to trichloramine (NCl(3)) in indoor swimming-pool environments is known to cause mucous membrane irritation, but if it gives rise to changes in lung function or asthma in adults is not known. (1) We determined lung function in volunteers before and after exposure to indoor pool environments. (2) We studied the occurrence of respiratory symptoms and asthma in a cohort of pool...

متن کامل

The Development and Validation of a Diffusive Sample with a Variable Sampling Rate for Long‐term Sampling of VOCs

PS 403‐17 Sampling and Analysis of Airborne Trichloramine in Indoor Swimming Pools T. Chu, S. Tsai, National Taiwan University, Taipei, Taiwan; S. Cheng, Council of Labor Affairs, Executive Yuan, Taipei, Taiwan. Objective: In swimming pools, visitors can contribute various kinds of organic nitrogen, such as sweat, or skin particles, which would react with chlorine to form trichloramine. It has...

متن کامل

Assessment of occupational and public exposure to trichloramine in Swiss indoor swimming pools: a proposal for an occupational exposure limit.

OBJECTIVES The presence of trichloramine in the air in different indoor swimming pools has been studied in several countries. In almost all studies, the results show a possible health impact due to trichloramine among pool attendants. The main objectives of our study were to evaluate, for the first time in Switzerland, occupational and public trichloramine exposure in a representative panel of ...

متن کامل

Application of an optimized system for the well-defined exposure of human lung cells to trichloramine and indoor pool air.

In this study an in vitro exposure test to investigate toxicological effects of the volatile disinfection by-product trichloramine and of real indoor pool air was established. For this purpose a set-up to generate a well-defined, clean gas stream of trichloramine was combined with biotests. Human alveolar epithelial lung cells of the cell line A-549 were exposed in a CULTEX(®) device with trich...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2007