Audiometric evaluation after stapedotomy with Fisch titanium prosthesis.

نویسندگان

  • Andre Luiz de Ataide
  • Gerson Linck Bichinho
  • Tatiana Mauad Patruni
چکیده

UNLABELLED Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis. OBJECTIVE This retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation. METHOD The criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests. RESULTS The mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under. CONCLUSION The Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

Comparison of the effectiveness of teflon piston and titanium stapes prosthesis in hearing improvement

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis. Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were rev...

متن کامل

Comparison of the Effectiveness of teflon piston and titanium stapes prosthesis in hearing improvement

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...

متن کامل

Audiometric Outcome Comparison between Titanium Prosthesis and Molded Autologous Material.

OBJECTIVE To evaluate and compare the audiometric outcomes of ossicular reconstruction with titanium prosthesis and autologous material. STUDY DESIGN Retrospective cohort study. SETTING Tertiary referral center. SUBJECTS AND METHODS Audiometric results of consecutive patients who performed ossiculoplasty with titanium prosthesis (n = 43) or autologous material (n = 48), from October 2008 ...

متن کامل

Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of otorhinolaryngology

دوره 79 3  شماره 

صفحات  -

تاریخ انتشار 2013