Pii: S0730-725x(01)00435-0

نویسندگان

  • Stephen E. Rose
  • Jonathan B. Chalk
  • Mark P. Griffin
  • Andrew L. Janke
  • Fang Chen
  • Geoffrey J. McLachan
  • David Peel
  • Fernando O. Zelaya
  • Hugh S. Markus
  • Derek K. Jones
  • Andrew Simmons
  • Michael O’Sullivan
  • Jo M. Jarosz
  • Wendy Strugnell
  • David M. Doddrell
  • James Semple
چکیده

In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (raCBF and raCBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean raCBF and raCBV values for eventually infarcted MTT tissue were 0.70 0.19 and 1.20 0.36. For recovered tissue the mean values were 0.99 0.25 and 1.87 0.71, respectively. There was a significant difference between these two regions for both measures (p 0.003 and p 0.001, respectively). Mean absolute measures of CBF (ml/100g/min) and CBV (ml/100g) for the total infarcted territory were 33.9 9.7 and 4.2 1.9. For recovered MTT tissue, the mean values were 41.5 7.2 and 5.3 1.2, respectively. A significant difference was also found for these regions (p 0.009 and p 0.036, respectively). The mean measures of sensitivity, specificity, positive and negative predictive values for modeling infarct evolution for the validation patient data were 0.72 0.05, 0.97 0.02, 0.68 0.07 and 0.97 0.02. We propose that this automated strategy may allow possible guided therapeutic intervention to stroke patients and evaluation of efficacy of novel stroke compounds in clinical drug trials. © 2001 Elsevier Science Inc. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0730-725x(01)00428-3

The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...

متن کامل

Pii: S0730-725x(01)00393-9

Electric Current Density Imaging (CDI) is a new modality of magnetic resonance imaging that enables electric current distribution imaging in conductive samples containing water. So far, two CDI techniques have been in use: DC-CDI operating at zero frequency and RF-CDI operating at the RF Larmor frequency. In this paper we present a new CDI technique, which extends the CDI frequency range to alt...

متن کامل

Pii: S0730-725x(01)00418-0

An important step in the analysis of fMRI time-series data is to detect, and as much as possible, correct for subject motion during the course of the scanning session. Several public domain algorithms are currently available for motion detection in fMRI. This paper compares the performance of four commonly used programs: AIR 3.08, SPM99, AFNI98, and the pyramid method of Thévenaz, Ruttimann, an...

متن کامل

Pii: S0730-725x(01)00404-0

In this work, computational methods were utilized to optimize the field produced by the transverse electromagnetic (TEM) resonator in the presence of the human head at 8 Tesla. Optimization was achieved through the use of the classical finite difference time domain (FDTD) method and a TEM resonator loaded with an anatomically detailed human head model with a resolution of 2 mm 2 mm 2 mm. The he...

متن کامل

Pii: S0730-725x(01)00436-2

Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001