RF Phase-Cycling Water-Saturated 3D b-SSFP for Fast Abdominal Fat Imaging

نویسندگان

  • Y. Ding
  • A. Zhou
  • R. W. McColl
  • P. T. Weatherall
  • Q. Peng
چکیده

Introduction Human body fat imaging and quantification is of great importance for clinical and research purposes. It is now established that excessive accumulation of regional adipose tissue, particularly intra-abdominal adipose tissue, is closely correlated with type II diabetes, cardiovascular disease, and cancer. T1-weighted (T1W) turbo spin-echo (TSE) is usually used for fat imaging because it offers a reasonable contrast-to-noise ratio (CNR) for fat to lean-tissue in a relatively short scan time. However, the contrast between fat and non-fat tissue in T1W TSE images is sometimes not sharp enough to differentiate fat reliably, especially when it is desired to use automatic or semi-automatic computer programs for fast post-processing. It was recently shown that a novel 3D water-saturated, balanced steady-state free-precession (WS b-SSFP) sequence can provide much higher acquisition bandwidth (BW) along frequencyand phase-encoding directions, thereby minimizing scan time as well as offering a high SNR and CNR [1]. However, the proposed 3D WS b-SSFP involves the synthesizer frequency shift from the system default water peak to fat frequency peak, so that banding artifacts can be avoided. Here we propose an RF phase-cycling approach (which is achieved by advancing the RF phase from cycle to cycle, as in an RF spoiled gradient echo sequence) to avoid banding artifacts. We hypothesize that the new clinically available technique can obtain the same fat image quality and fat volume accuracy as the one described in [1], but with greatly reduced technical difficulties under the clinical settings. Theory It has been shown that RF phase-cycling in the transmitter and the receiver in b-SSFP sequences can be used to simulate resonant frequency offsets [2]. Let f0 be the frequency of the water peak defined by the default synthesizer frequency setting. By using a phase-cycling step of π, a b-SSFP signal plateau is centered at the water peak. To achieve a frequency offset of ∆υ (simulating an f0 shift of ∆υ), the phase of every RF pulse (and the phase of every ADC) is incremented by φ=π+2π∆υTR radians. Therefore, to achieve a -220Hz shift to get optimized fat imaging in a TR=2.9ms b-SSFP sequence, the phase cycling step is φ=0.28π, which is tested in this study. The simulated spectral responses of the original sequence with the phase cycling step of φ=π (blue curve), and the new one with step of φ=-0.28π (red curve) are shown in Fig. 1. Methods 3 healthy volunteers underwent abdomen imaging in a 1.5 T clinical MR scanner (Philips Gyroscan Intera, Release 11.1) using a standard quadraturebody coil. The same 3D WS b-SSFP sequence described in [1] was employed. The default phase cycling step of the sequence was π. To achieve optimal fat imaging, the synthesizer frequency was first shifted to resonant frequency of fat (a shift of -220Hz) before 3D WS b-SSFP scans were acquired (f0 shift approach). For comparison, the same protocol was repeated without synthesizer frequency shift, but with a different b-SSFP phase cycling scheme (phase step is now -0.28π, the phase-cycling approach). Other image parameters were the same as in [1]. Scan duration was 11 seconds for each of the two sequences. To study the variations, the phase-cycling approach was repeated on every subject. All three series of images were imaged with breath-hold to reduce motion artifacts. Image processing was accomplished using a newly developed fully automated software package (Q-Fat) which will be reported elsewhere. Briefly, the subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) were automatically segmented and the fat volumes were quantified respectively. In addition, an automatically optimized thresholding mask was applied before the fat area on each ROI was quantified [3]. Results Example images obtained using the traditional f0 shift approach and the phase-cycling approach are shown in Fig. 2. There is no image quality difference from visual inspection; although bowel motion between scans induces fat distribution change. No banding artifacts are noticed on phase-cycling WS b-SSFP images (Fig. 2b). Automated fat quantification results on each subject are shown in Table 1. The difference percentage is defined as the percentage difference of fat area estimated on f0 shift images and the average of the two phase-cycling areas. It is shown that difference on SAT is small (<0.87%) but VAT is much larger (<4.92%). However, the average difference percentage of the three subjects of VAT is only 0.45%. Discussion and Conclusions It is shown here theoretically and experimentally that the phase-cycling WS b-SSFP generates fat only images with the same image quality, and very close fat quantification results as the traditional f0 shift approach. Fat quantification on VAT resulted in much larger difference than on SAT, which can be explained by the bowel motion induced fat distribution rearrangement between imaging scans. The fully automated fat quantification algorithm may introduce some variations due to the segmentation difficulties on VAT as well as SAT. The average differences on SAT and VAT are 0.03% and 0.45% respectively, which shows that the proposed method has little or no bias when used for abdominal fat imaging. We conclude that the clinically available RF phase-cycling WS 3D b-SSFP can replace the previously reported manual f0 shift approach for abdominal fat imaging. References 1. Peng Q, et al, “Water-Saturated 3D Balanced Steady-State Free Precession for Fast Abdominal Fat Quantification”, JMRI. 21(3):263-71, 2005. 2. Deshpande V, et al, “Artifact Reduction in True-FISP Imaging of the Coronary Arteries by Adjusting Imaging Frequency”, MRM. 49:p803-9, 2003. 3. Peng Q, et al, “Automated Method for Accurate Abdominal Fat Quantification on Water-Saturated Magnetic Resonance Images”, JMRI. 26(3): 738-46, 2007 Table 1. Comparison of Fat Quantification Results (unit: 100 cm)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separa...

متن کامل

Integration of magnetization preparation sequences into SSFP sequences: A fat saturation example

Introduction: Steady state MRI-sequences are widely used for clinical applications. In particular, balanced steady-state free precession (b-SSFP) has become increasingly important for diagnostic and interventional imaging [1]. However, contrast modification by using magnetization preparation sequences, (like fat suppression or regional signal suppression), requires the use of transient steady s...

متن کامل

Robust Multicoil Reconstruction for Phase-Sensitive Fat-Water Separation

Introduction: Phase-sensitive (PS) SSFP [1,2] is an efficient fat/water separation method, successfully used in several applications including angiography [1], musculoskeletal [3] and abdominal [4] imaging. It generates and detects a 180 phase-difference between fat and water. In previous work, water images reconstructed from individual coils with PSSSFP were combined [4,5]. However, abrupt spa...

متن کامل

Ultrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast

INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...

متن کامل

Fast 3D H Spectroscopic Imaging of the Human Brain at 3 Tesla using “spectroscopic Missing Pulse – SSFP” with 3D Spatial Selection

C. Schuster, W. Dreher, D. Leibfritz FB 2 (Chemistry), University of Bremen, Bremen, Germany, Center of Advanced Imaging (CAI), Bremen, Germany Introduction Over the past years several methods for fast 3D H MR spectroscopic imaging (MRSI) derived from corresponding fast MRI methods have been proposed to map the distribution of human brain metabolites. Besides echo planar MRSI and spiral MRSI [1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007