A method is described for analysis of nickel in serum and heparinized blood. After the sample has been subjected to protein precipitation with nitric acid and heat, nickel in the protein-free extract is measured by electrothermal atomic absorption with Zeeman background correction. The method is more sensitive, rapid, and convenient than previous techniques, and less subject to nickel contamination. Nickel concentrations in serums from New Zealand rabbits (mean +/- SD) average 4.0 +/- 2.5 micrograms per L, range = 0.9 to 11.9, N = 30; these results agree with measurements by the International Union of Pure and Applied Chemistry (IUPAC) reference procedure ( corr . coef . = 0.98). The following values are reported for nickel concentrations in serum and whole blood from healthy adult persons living in central Connecticut: serum, 0.46 +/- 0.26 micrograms per L, range = 0.1 to 1.3, N = 39; whole blood, 1.26 +/- 0.33 micrograms per L, range = 0.6 to 1.8, N = 30. This method is suitable for routine use in clinical and industrial laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood nickel concentrations in patients with stainless-steel hip prostheses.

Nickel concentrations were analyzed by electrothermal atomic absorption spectrophotometry in serum and whole blood specimens from patients 9 to 15 years after unilateral (N = 11) or bilateral (N = 2) hip arthroplasty. The hip prostheses were of the "Charnley" or "TR-28" (metal-to-plastic) types, fabricated of stainless-steel (14 to 16 percent Ni) with polyethylene acetabular cups. In 12 of the ...

متن کامل

Determination of nickel in biological samples prepared by microwave dissolution using electrothermal atomic absorption spectrometry after extraction with l,Sbis[phenyl-( 2-pyridyl) methylene] thiocarbonhydrazide

An electrothermal atomization atomic absorption spectrometric method for the determination of traces of nickel atIer extraction of the metal into methyl isobutyl ketone containing 1,5-bis[phenyl(2-pyridylhnethylene] thiocarbonhydrazide is suggested. The chief advantage of the method lies in its maximum allowable aqueous-to-organic phase volume ratio of 37. The method was applied to the determin...

متن کامل

Determination of arsenic in biological fluids by electrothermal atomic absorption spectrometry.

A procedure for the determination of the total content of arsenic in urine, serum and blood by electrothermal atomic absorption spectrometry (ETAAS) is described. Zeeman correction is used to compensate the high background signals. The samples are diluted (1 + 1 for urine and 1 + 3 for both serum and blood samples) in a medium containing 0.1% w/v Triton X-100 before being introduced directly in...

متن کامل

Hypernickelemia following coronary arteriography, caused by nickel in the radiographic contrast medium.

Meglumine diatrizoate ("Renografin-76", a radiographic contrast medium) contains sufficient nickel to cause hypernickelemia in patients after coronary arteriography. Nickel analyses by electrothermal atomic absorption spectrophotometry showed that nine lots of "Renografin-76" (760 g of meglumine diatrizoate per L) contained 144 +/- 44 micrograms Ni per L. Serum Ni concentrations became elevated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید