Model-based optimal PEEP in mechanically ventilated ARDS patients in the Intensive Care Unit
نویسندگان
چکیده
BACKGROUND The optimal level of positive end-expiratory pressure (PEEP) is still widely debated in treating acute respiratory distress syndrome (ARDS) patients. Current methods of selecting PEEP only provide a range of values and do not provide unique patient-specific solutions. Model-based methods offer a novel way of using non-invasive pressure-volume (PV) measurements to estimate patient recruitability. This paper examines the clinical viability of such models in pilot clinical trials to assist therapy, optimise patient-specific PEEP, assess the disease state and response over time. METHODS Ten patients with acute lung injury or ARDS underwent incremental PEEP recruitment manoeuvres. PV data was measured at increments of 5 cmH2O and fitted to the recruitment model. Inspiratory and expiratory breath holds were performed to measure airway resistance and auto-PEEP. Three model-based metrics are used to optimise PEEP based on opening pressures, closing pressures and net recruitment. ARDS status was assessed by model parameters capturing recruitment and compliance. RESULTS Median model fitting error across all patients for inflation and deflation was 2.8% and 1.02% respectively with all patients experiencing auto-PEEP. In all three metrics' cases, model-based optimal PEEP was higher than clinically selected PEEP. Two patients underwent multiple recruitment manoeuvres over time and model metrics reflected and tracked the state or their ARDS. CONCLUSIONS For ARDS patients, the model-based method presented in this paper provides a unique, non-invasive method to select optimal patient-specific PEEP. In addition, the model has the capability to assess disease state over time using these same models and methods.
منابع مشابه
Feasibility of titrating PEEP to minimum elastance for mechanically ventilated patients
BACKGROUND Selecting positive end-expiratory pressure (PEEP) during mechanical ventilation is important, as it can influence disease progression and outcome of acute respiratory distress syndrome (ARDS) patients. However, there are no well-established methods for optimizing PEEP selection due to the heterogeneity of ARDS. This research investigates the viability of titrating PEEP to minimum ela...
متن کاملUneven distribution of ventilation in acute respiratory distress syndrome
INTRODUCTION The aim of this study was to assess the volume of gas being poorly ventilated or non-ventilated within the lungs of patients treated with mechanical ventilation and suffering from acute respiratory distress syndrome (ARDS). METHODS A prospective, descriptive study was performed of 25 sedated and paralysed ARDS patients, mechanically ventilated with a positive end-expiratory press...
متن کاملThe Elixir of Visiting: A Qualitative Study on the Experiences of Conscious Mechanically Ventilated Patients in Intensive Care Units Regarding Visiting Family Members
Background: Visiting family members is one of the basic human needs; however, there is contradictory evidence about the advantages and disadvantages of the existing visiting systems. Therefore, the investigation of patients’ preferences for the visiting strategies, and achievement of their authentic experiences can significantly contribute to decision-making about the type of acceptable and ap...
متن کاملEffect of Acupressure on Gastric Content Aspiration in Mechanically Ventilated Patients Hospitalized in Intensive Care Units
Background and Objectives: Aspiration is a serious complication that occurs due to delayed gastric emptying in mechanically ventilated patients. Aspiration results in increased rate of pneumonia and death. Acupressure can increase gastric motility and prevent aspiration. This study aimed to determine the effect of acupressure on occurrence of gastric content aspiration in mechanically ventilate...
متن کاملEvaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.
STUDY OBJECTIVE To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN An open comparison between two methods using a criterion standard. E...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2011