Capillary electrophoresis-electrospray ionization mass spectrometry for rapid and sensitive N-glycan analysis of glycoproteins as 9-fluorenylmethyl derivatives.
نویسندگان
چکیده
It is well known that most protein therapeutics such as monoclonal antibody pharmaceuticals and other biopharmaceuticals including cancer biomarkers are glycoproteins, and thus the development of high-throughput and sensitive analytical methods for glycans is essential in terms of their determination and quality control. We previously reported a novel alternative labeling method for glycans involving 9-fluorenylmethyl chloroformate (Fmoc-Cl) instead of the conventional reductive amination procedure. The derivatives were analyzed by high-performance liquid chromatography (HPLC) (Kamoda S, Nakano M, Ishikawa R, Suzuki S, Kakehi K. 2005. Rapid and sensitive screening of N-glycans as 9-fluorenylmethyl derivatives by high-performance liquid chromatography: A method which can recover free oligosaccharides after analysis. J Proteome Res. 4:146-152). This method was rapid and simple; however, it was time-consuming in terms of analysis by HPLC and did not provide so much information such as the detailed structures and mass numbers of glycans. Here we have developed a high-throughput and highly sensitive method. It comprises three steps, i.e., release of glycans, derivatization with Fmoc, and capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI MS) analysis. We analyzed several glycoproteins such as fetuin, alpha1 acid glycoprotein, IgG, and transferrin in order to validate this method. We were able to analyze the above glycoproteins with the three-step procedure within only 5 h, which provided detailed N-glycan patterns. Moreover, the MS/MS analysis allowed identification of the N-glycan structures. As novel applications, the method was employed for the analysis of N-glycans derived from monoclonal antibody pharmaceuticals and also from alpha-fetoprotein; the latter is known as one of the tumor markers of hepatocellular carcinomas. We were able to easily and rapidly determine the detailed structures of the N-glycans. The present method is very useful for the analysis of large numbers of samples such as a routine analysis.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملAnalysis of phospholipase A2 glycosylation patterns from venom of individual bees by capillary electrophoresis/electrospray ionization mass spectrometry using an ion trap mass spectrometer.
A method based on tryptic digestion, ultrafiltration and capillary electrophoresis/mass spectrometry (CE/MS) has been developed for the analysis of the glycosylation pattern in the phospholipase A2 (PLA) of individual honeybees. Without reducing the disulfide bonds, PLA was digested with trypsin and filtered with a 3 kDa molecular weight (MW) cut-off membrane. With this procedure, the glycopept...
متن کاملRapid Biomolecule Analysis Using Two-dimensional Electrophoresis-electrospray Ionization Microchip
We demonstrate a two-dimensional (2D) separation microchip allowing capillary isoelectric focusing-capillary zone electrophoresis (cIEF-CZE) to be coupled to electrospray ionization mass spectrometry (ESI/MS). In the first dimension, separation is according to pI values (cIEF), while CZE occurs in the second dimension during mobilization towards the monolithically integrated ESI emitter. The se...
متن کاملAnalysis of hop acids and their oxidized derivatives and iso-alpha-acids in beer by capillary electrophoresis-electrospray ionization mass spectrometry.
This study investigates the applicability of on-line coupling of capillary electrophoresis with electrospray ionization tandem mass spectrometry (CZE-ESI-MS) for the separation and characterization of alpha- and beta-acids and oxidized hop acids from crude extracts of different hop varieties. CZE-ESI-MS with negative-ion electrospray ionization proved to be a suitable technique for the determin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Glycobiology
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2009