Hemodynamic Fingerprinting of Altered 3D Blood Characteristics in Aortic Disease

نویسندگان

  • Julio Garcia
  • Alex J. Barker
  • Pim van Ooij
  • Susanne Schnell
  • S. Chris Malaisrie
  • Jeremy Collins
  • James Carr
  • Michael Markl
چکیده

Purpose: Time-resolved 3D PC-MRI with threedirectional velocity encoding (4D flow MRI) has been successfully applied in a number of studies for the analysis of altered hemodynamics in patients with cardiovascular disease. Data analysis, however, can be time consuming and often relies on the manual placement of 2D analysis planes at user defined vascular regions of interest. The analysis of flow parameters and derived metrics of hemodynamics are thus often limited by observer variability. In addition, the inherent volumetric 3D coverage of the vascular system of interest provided by 4D flow MRI is not fully utilized by analysis based on 2D planes. Nevertheless, a number of studies have shown that 4D flow MRI can detect the impact of vascular disease on changes in vascular hemodynamics. It was thus the aim of this study to evaluate a novel automated flow distribution analysis based on the evaluation the blood flow velocity distributions in the entire 3D vessel segments to identify hemodynamic ‘fingerprints’ of different aortic pathologies. Our goal was to test the feasibility of invivo hemodynamic fingerprinting to identify altered 3D flow characteristics in patients with aortic dilation and aortic valve stenosis without the need for the manual definition of 2D analysis planes. Methods: 40 subjects (10 controls and 30 patients with aortic dilation and tricuspid aortic valves) (age=56±17 years, female=11) were identified via an IRB-approved retrospective chart review. The mid-ascending aorta (MAA) diameter was used to stratify by aortic (Ao) dilation and aortic valve peak velocity (PV) was used to determine the presence of aortic valve stenosis (AS). Each subject was classified into four groups: controls (n=10, MAA<35 mm and PV<1.5 m/s); moderate Ao dilation (n=10, 3545 mm and PV<1.5 m/s); Ao dilation + AS (n=10, MAA>35 mm and PV>1.5 m/s). 4D flow MRI was performed at 1.5T and 3T with full 3D coverage of the thoracic aorta (spatial resolution=2.5×2.1×3.2 mm; temporal resolution=40-50 ms) using prospective ECG gating and a respiratory navigator gating. Pulse sequence parameters were as follows: 1.5 T scan parameters ranged from TE/TR=2.3–3.4/4.8–6.6 ms, flip angle α=7–15° and a field of view of 340–400×200–300 mm; 3T scans used TE/TR =2.5/5.1 ms, flip angle α=7–15°, and a field of view of 400×308 mm. 3D PC-MR angiograms were computed and used to obtain a 3D segmentation of the aorta (Mimics, Materialise, Leuven, Belgium). Based on the segmentation, 4 aortic sub-regions were analyzed (see Fig. 1), including: Segment 1, traversing the left ventricle outflow tract to the sinotubular junction; Segment 2, which progresses from the sino-tubular junction to the aortic arch; Segment 3, which covers the aortic arch; and Segment 4, which includes the proximal descending aorta. The four vascular 3D segments were used to compute a masked 4D velocity field (3 spatial dimensions + time) for each aortic segment. The masked aorta velocity fieled was used to generate a time-resolved maximum intensity projection (MIP) in an oblique sagittal plane using the three peak systolic velocity phases, Fig. 1A. The velocities for all voxels and cardiac time-frames inside an aortic segment were plotted in histogram form and normalized by the total number of voxels in order to create a cohort-specific hemodynamic fingerprint that can be compared across subjects and cohorts. In addition, mean, median, standard deviation, and the normalized number of voxels >1m/s (incidence) were calculated as shown in Fig. 1B for Segment 2 (Matlab, Natick, MA, USA). A sensitivity analysis was conducted to identify which proportions of the velocity distribution (number of time frames and top % of velocities) were most sensitive to differences in flow distribution between patient groups and controls. At each threshold, a t-test was conducted to evaluate the significance of difference between groups and it was determined that the first 8 time steps of the cardiac cycle (320-400ms) and 100% of the data were optimal for the detection of cohort differences. Results: Subject characteristics are summarized in Table 1. All subjects had normal ejection fraction (60±7%), although severe Ao Dilation was significantly elevated (p<0.05 vs. Controls). Examples of velocity MIPs in Fig. 1A visually illustrate disease specific differences in the aortic velocity patterns and distribution. The appearance of the patient flow patterns, as seen in the velocity MIPs, were heterogeneous compared to controls. The dilated aortas displayed outflow jets and high flow regions (red color) which were most pronounced for the AS patients. Examples of spider web plots for flow parameter fingerprints are shown in Fig. 1C, which provide a visual impression of the flow characteristics. The velocity histogram parameters are shown in Fig. 1C-F. The mean velocity for Ao Dilation+AS was significantly different from other groups in all segments due to aortic stenosis, Fig. 1C. Interestingly for median velocities, Segment 2 showed a significant difference between moderate Ao Dilation and Ao Dilation+AS, Fig. 1D. These differences may be due to the severity of Ao dilation and helical flow in groups with Ao dilation. For almost all segments, the velocity standard deviation was significantly higher for Ao Dilation+AS vs. other groups (Fig. 1E). The incidence for velocities > 1 m/s was significantly increased for Ao Dilation+AS in segment 1 due to valve stenosis. Discussion: The volumetric velocity distribution analysis presented here has demonstrated: 1) 3D blood flow velocity distributions may identify hemodynamic fingerprints of different aortic pathologies via basic statistical descriptors (i.e. mean, median, standard deviation and incidence), and 2) the characterization of hemodynamic fingerprints along regional aortic segments in subjects with aortic disease. The automatic distribution analysis of 4D flow data may be useful in the automated characterization or hemodynamic ‘fingerprinting’ of cardiovascular disease by identifying simple characteristic parameters associated with the presence of pathology. The results indicate a selection of blood flow behaviours which are capable of stratifying the presence of disease, as shown for Ao Dilation+AS group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV

Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D cl...

متن کامل

Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation

Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-establish...

متن کامل

The Hemodynamic Effects of Drugs on Myocardial Oxygen Use

The circulatory responses to high equinalgesic doses of morphine are compared with those of pethidin. The decrease in mean arterial blood pressure in case of morphine was 28p.c., with a paralleled and identical de­crease in total peripheral resistance and no negative inotropic effects.  Pethidine decreased blood pressure 54p.c., as a result of peripheral vasodilation of 46p.c. and a sharp drop...

متن کامل

Management of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report

Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75&ndash;years-o...

متن کامل

Neonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass.

The objective of this study is to quantify the detailed three-dimensional (3D) pulsatile hemodynamics, mechanical loading, and perfusion characteristics of a patient-specific neonatal aortic arch during cardiopulmonary bypass (CPB). The 3D cardiac magnetic resonance imaging (MRI) reconstruction of a pediatric patient with a normal aortic arch is modified based on clinical literature to represen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013