Imaging for suspected pulmonary embolism in pregnancy—what about the fetal dose? A comprehensive review of the literature

نویسندگان

  • Tilo Niemann
  • Guillaume Nicolas
  • Hans W. Roser
  • Jan Müller-Brand
  • Georg Bongartz
چکیده

OBJECTIVE: To give a comprehensive overview of fetal doses reported in the literature when imaging the pregnant woman with suspected pulmonary embolism (PE). METHODS: A comprehensive literature search in the PubMed, MEDLINE and EMBASE databases yielded a total of 1,687 papers that were included in the analysis and have been analysed with regard to fetal dose in suspected PE radiological imaging strategies. RESULTS: Fetal dose in chest computed tomography (CT) ranges between 0.013 and 0.026 mGy in early and 0.06-0.1 mGy in late pregnancy compared with 99mTc-MAA perfusion scintigraphy with a fetal dose of 0.1-0.6 mGy in early and 0.6-0.8 mGy in late pregnancy. (99m)Tc-aerosol ventilation scintigraphy results in 0.1-0.3 mGy. However, there is concern about female breast irradiation in CT, which is higher than in scintigraphy. CT radiation risks for breast tissue remain unclear. CONCLUSION: Knowledge of dosimetry and radiation risks is crucial in the radiological work-up of suspected PE in pregnancy. It is reasonable to reserve scintigraphy for pregnant patients with normal chest radiography findings and no history of asthma or chronic lung disease. Performing CT applying dose reduction instead of scintigraphy will minimise fetal radiation dose and maximise the diagnostic value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Evaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography

    Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...

متن کامل

Preoperative Emboli in a Pregnant Woman with Myxoma

The left atrium is the most common location of myxomas, which are benign tumors. Only a few cases of myxomas in pregnancies have been reported. Our thorough medical literature search showed only 17 reported cases in the course of pregnancy. Myxomas during pregnancy and in the preterm period constitute a serious phenomenon that can mimic an early sign of a life-threatening pathology like severe ...

متن کامل

[Diagnostic imaging during pregnancy].

If diagnostic imaging during pregnancy is performed, potential risks not only for the mother but also for the fetus have to be considered. Ultrasonography should be performed primarily because it is harmless for the fetus. Other imaging modalities like x-ray, computed tomography (CT) and magnetic resonance imaging (MRI) should be reserved for cases in which results of ultrasonography are inconc...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2010