Bite-Block Relocation Error in Image-Guided Otologic Surgery
نویسندگان
چکیده
Otologic surgery is undertaken to treat ailments of the ear including persistent infections, hearing loss, vertigo, and cancer. Typically performed on healthy patients in outpatient facilities, the application of image-guided surgery has been limited because accurate (<1mm), non-invasive fiducial systems for otologic surgery are not available. We have developed such a system, which repeatably attaches to a subject via a dental bite block [1]. In a previous report, ex-vivo validation indicated that mean target registration error ± standard deviation for 234 targets within the surgical field was 0.73±0.23mm with a root mean square of 0.77mm [2,3]. In an effort to further understand the limitations of our system, we undertook, and report herein, a detailed error analysis to determine what portion of the error is attributable to the inaccuracies in relocation fit of the fiducial frame to a subject’s dentition. Our analysis shows that the root-mean-square error due to relocation alone is approximately 0.66 mm, while that due to fiducial registration is approximately 0.30 mm.
منابع مشابه
Submillimetric target-registration error using a novel, non-invasive fiducial system for image-guided otologic surgery.
OBJECTIVE Otologic surgery is undertaken to treat ailments of the ear, including persistent infections, hearing loss, vertigo, and cancer. Typically performed on otherwise-healthy patients in outpatient facilities, the application of image-guided surgery (IGS) has been limited because accurate (<1 mm), non-invasive fiducial systems for otologic surgery have not been available. We now present su...
متن کاملValidation of a Fiducial Frame System for Image-guided Otologic Surgery Utilizing Baha® Bone Screws
Image-guided otologic surgeries performed on healthy patients require non-invasive fiducial systems that achieve submillimetric target registration error (TRE). We have described such a system that attaches repeatably to a subject via a dental bite block [1]. We now describe a new method for the clinical validation of such a system that can be conducted in the laboratory with no intraoperative ...
متن کاملClinical Determination of Target Registration Error of an Image- Guided Otologic Surgical System using Patients with Bone-Anchored Hearing Aids
Image guidance in otologic surgery has been thwarted by the need for a non-invasive fiducial system with target registration error (TRE) at the inner ear below 1.5mm. We previously presented a fiducial frame for this purpose that attaches to the upper dentition via patient-specific bite blocks and demonstrated a TRE of 0.73mm (±0.23mm) on cadaveric skulls. In that study, TRE measurement depende...
متن کاملMinimally invasive, image-guided, facial-recess approach to the middle ear: demonstration of the concept of percutaneous cochlear access in vitro.
HYPOTHESIS Image-guided surgery will permit accurate access to the middle ear via the facial recess using a single drill hole from the lateral aspect of the mastoid cortex. BACKGROUND The widespread use of image-guided methods in otologic surgery has been limited by the need for a system that achieves the necessary level of accuracy with an easy-to-use, noninvasive fiducial marker system. We ...
متن کاملImage-guided otologic surgery
Application of image-guided surgical systems to otologic surgery has been limited by the need for submillimeter accuracy via a fiducial system that is easily useable (i.e. noninvasive and nonobstructive). To overcome these limitations and demonstrate the feasibility of image-guided otologic surgery, a novel fiducial marker system was constructed which attaches to a dental biteblock and has fidu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -