Feasibility study on Generalized-Aurora Computed Tomography
نویسندگان
چکیده
Aurora Computed Tomography (ACT) is a method for retrieving the three-dimensional (3-D) distribution of the volume emission rate from monochromatic auroral images obtained simultaneously by a multi-point camera network. We extend this method to a Generalized-Aurora Computed Tomography (G-ACT) that reconstructs the energy and spatial distributions of precipitating electrons from multi-instrument data, such as ionospheric electron density from incoherent scatter radar, cosmic noise absorption (CNA) from imaging riometers, as well as the auroral images. The purpose of this paper is to describe the reconstruction algorithm involved in this method and to test its feasibility by numerical simulation. Based on a Bayesian model with prior information as the smoothness of the electron energy spectra, the inverse problem is formulated as a maximization of posterior probability. The relative weighting of each instrument data is determined by the crossvalidation method. We apply this method to the simulated data from real instruments, the Auroral Large Imaging System (ALIS), the European Incoherent Scatter (EISCAT) radar at Tromsø, and the Imaging Riometer for Ionospheric Study (IRIS) at Kilpisjärvi. The results indicate that the differential flux of the precipitating electrons is well reconstructed from the ALIS images for the low-noise cases. Furthermore, we demonstrate in a case study that the ionospheric electron density from the EISCAT radar is useful for improving the reconstructed electron flux. On the other hand, the incorporation of CNA data into this method is difficult at this stage, because the extension of energy range to higher energy causes a difficulty in the reconstruction of the low-energy electron flux. Nevertheless, we expect that this method may be useCorrespondence to: Y.-M. Tanaka ([email protected]) ful in analyzing multi-instrument data and, in particular, 3-D data, which will be obtained in the upcoming EISCAT 3D.
منابع مشابه
The feasibility of direct treatment planning via contrast-enhanced computed tomography: an evaluation of dose differences based on the dimensional dose distribution comparison method
Background: We used a MapCHECK software-based dimensional dose distribution comparison method capable of evaluating point-to-point geometrical dose differences in volume to determine whether doses obtained from an enhanced computed tomography (CT)-based treatment plan, which better defines the target regions and organs at risk, differs from doses obtained from plain CT and then evaluated the fe...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملMega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.
Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...
متن کاملComparison between Needle Biopsy under Guide of Conventional Computerized Tomography (CCT) and Fluoroscopic Computerized Tomography (FCT) in Abdominal, Mediastinal, Lung, Pelvic, Bone, and Liver Masses
Background and Objective: Computerized tomography and fluoroscopic computerized tomography are amongst the methods used for guiding needle biopsy processes; however, fluoroscopic computerized tomography demonstrates the images during the process of biopsy. This study aims to compare and contrast the success of biopsy under guide...
متن کاملOptimal timing of computed tomography for assessing lymph nodes after neoadjuvant chemoradiotherapy for rectal cancer
Background: This study assessed the optimal timing of computed tomography for detection of metastatic disease in locoregional lymph nodes in patients with rectal cancer who have undergone chemoradiotherapy. Materials and Methods: This observational retrospective study was performed in a single institution. All patients with locally advanced rectal cancer treated with chemoradiotherapy, followed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011