Prolonged vibration of the biceps brachii tendon reduces time to failure when maintaining arm position with a submaximal load.
نویسندگان
چکیده
Vibration reduces the amplitudes of the tendon jerk response and the Hoffmann and stretch reflexes in the muscle exposed to the vibration, yet does not alter the time to task failure when the task involves exerting a submaximal force against a rigid restraint. Because the amplitude of the stretch reflex is greater when a limb acts against a compliant load than a rigid restraint, the purpose was to determine the influence of prolonged tendon vibration on the time to failure when maintaining limb position with the elbow flexor muscles. Twenty-five healthy men performed the fatiguing contraction by maintaining elbow angle at 1.57 rad until failure while supporting a load equal to 20% of maximal voluntary contraction (MVC) force. The fatiguing contraction was performed on 3 separate days with different levels of vibration applied to the biceps brachii tendon: no vibration, subthreshold for a tonic vibration reflex (TVR), and suprathreshold for a TVR. MVC force before the fatiguing contraction was similar across the three sessions (mean of 3 sessions: 313 +/- 54 N, P = 0.83). Despite a similar decline in MVC force after the fatiguing contraction across conditions (-18.0 +/- 8.0%, P > 0.05), the time to task failure was 3.7 +/- 1.4 min for the suprathreshold TVR condition, 4.3 +/- 2.1 min for the subthreshold TVR condition, and 5.0 +/- 2.2 min for the no-vibration condition (P < 0 0.001). The average EMG of the elbow flexor muscles was similar (P = 0.22) during the fatiguing contractions. However, the fluctuations in limb acceleration at task onset were greater for the suprathreshold TVR condition (P < 0.01), but were not different between the subthreshold TVR and no-vibration conditions (P > or = 0.22). Furthermore, the difference in the SD of limb acceleration between the no-vibration and vibration conditions was correlated with the difference in time to failure for the no-vibration and subthreshold TVR conditions (P = 0.03; r2 = 0.22), but not for the no-vibration and suprathreshold TVR conditions (P = 0.90; r2 = 0.001). These findings indicate that prolonged vibration reduced the time to failure of a sustained contraction when subjects maintained limb position, suggesting that peripheral inputs to the motor neuron pool play a significant role in sustaining a contraction during tasks that require active control of limb position.
منابع مشابه
Contraction of body representation induced by proprioceptive conflict
Our body is not only an extended object in external space, but also the basis of our sense of self. Proprioceptive signals from muscle spindle organs, specifying body position, play a key role in this unique dual quality of body representation, as they define a ‘here’ or set of locations, where ‘I’ am located [1]. Position information from muscle spindles can be manipulated by vibrating the mus...
متن کاملNo Telescoping Effect with Dual Tendon Vibration
The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an incon...
متن کاملMotor unit activity in biceps brachii of left-handed humans during sustained contractions with two load types.
The purpose of the study was to compare the discharge characteristics of single motor units during sustained isometric contractions that required either force or position control in left-handed individuals. The target force for the two sustained contractions (24.9 ± 10.5% maximal force) was identical for each biceps brachii motor unit (n = 32) and set at 4.7 ± 2.0% of maximal voluntary contract...
متن کاملThe effect of biceps reattachment site.
BACKGROUND We hypothesize that an anatomic repair of the distal biceps tendon would recreate native tendon moment arm and forearm rotation, while a nonanatomic insertion would compromise moment arm and forearm rotation. METHODS Isometric supination torque was measured at 60° of pronation, neutral, and 60° of supination for the native distal biceps tendon and 4 repair points in 6 cadaveric spe...
متن کاملFacilitation of triceps brachii muscle contraction by tendon vibration after chronic cervical spinal cord injury.
One way to improve the weak triceps brachii voluntary forces of people with chronic cervical spinal cord injury may be to excite the paralyzed or submaximally activated fraction of muscle. Here we examined whether elbow extensor force was enhanced by vibration (80 Hz) of the triceps or biceps brachii tendons at rest and during maximum isometric voluntary contractions (MVCs) of the elbow extenso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurophysiology
دوره 95 2 شماره
صفحات -
تاریخ انتشار 2006