A method for direct estimation of imprecision profiles, with reference to immunoassay data.
نویسندگان
چکیده
A three-parameter model for directly estimating imprecision profiles from replicated immunoassay results is compared with a six-parameter indirect profile model obtained by the usual method of combining error in the raw response measurements with the slope of the standard curve. Direct estimation is likely to be less reliable when based on the limited data collected from a single assay, and may underestimate variability at high concentrations when many results are clustered at the upper end of the concentration range. However, at concentrations near the assay detection limit (often a region of particular interest), direct estimation is superior to the indirect method if a logistic or related function is used as the standard curve model. Direct estimation of imprecision profiles has useful application whenever the internal details of an assay system are not readily available, for example, in analysis of data collected in external surveys.
منابع مشابه
Use and Abuse of Imprecision Profiles: Some Confidence Intervals
Published estimates of the imprecision characteristics of immunoassays are often based on quantities of data that seem to be inadequate. The increasing use of imprecision profiles has not necessarily improved the situation. We describe and illustrate a method of computing 95% confidence intervals for profiles estimated directly from replicated assay results. The data used were chosen to mimic t...
متن کاملReference Values for Serum Lipid Profiles in Iranian Adults: A Spline-Based Quantile Regression Method
Background: Reference measurements are used to screen for abnormal blood lipids. The problem is that these reference values obtained in one population cannot be effective for another population. This study aimed to determine the reference values for blood lipids profiles in the population aged 25-64 years in Yazd. Methods: This descriptive study was based on the data of Yazd Health Study (YaHS...
متن کاملA Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma
Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten t...
متن کاملA Simple Sample Preparation with HPLC-UV Method for Estimation of Clomipramine from Plasma
Clomipramine is a tricyclic antidepressant. Different methods for determination of clomipramine hydrochloride in plasma have been described. Most of these procedures favor the use of acidic back-extraction in extraction procedure and HPLC as the analytical technique. In this study, the clomipramine extraction procedure was modified and a direct injection to the column was performed to shorten t...
متن کاملEstablishment of Reference Interval for Homeostasis Model Assessment of Insulin Resistance in Healthy Adult Males: a Pilot Study in Alexandria Governorate, Egypt
Abstract Objective: Homeostasis model assessment of insulin resistance (HOMA-IR) is a simple and practical method for estimation of insulin resistance (IR), but a reliable reference interval (RI) of HOMA-IR is needed to deduce the threshold level to define IR. This RI has been controversial in different populations and even more divergent when considering factors like age, gender and body mass...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 34 6 شماره
صفحات -
تاریخ انتشار 1988