Multiplexing Prisms for Field Expansion.
نویسندگان
چکیده
PURPOSE Prisms used for field expansion are limited by the optical scotoma at a prism apex (apical scotoma). For a patient with two functioning eyes, fitting prisms unilaterally allows the other eye to compensate for the apical scotoma. A monocular patient's field loss cannot be expanded with a conventional or Fresnel prism because of the apical scotoma. A newly invented optical device, the multiplexing prism (MxP), was developed to overcome the apical scotoma limitation in monocular field expansion. METHODS A Fresnel-prism-like device with alternating prism and flat elements superimposes shifted and see-through views, thus creating the (monocular) visual confusion required for field expansion and eliminating the apical scotoma. Several implementations are demonstrated and preliminarily evaluated for different monocular conditions with visual field loss. The field expansion of the MxP is compared with the effect of conventional prisms using calculated and measured perimetry. RESULTS Field expansion without apical scotomas is shown to be effective for monocular patients with hemianopia or constricted peripheral field. The MxPs are shown to increase the nasal field for a patient with only one eye and for patients with bitemporal hemianopia. The MxPs placed at the far temporal field are shown to expand the normal visual field. The ability to control the contrast ratio between the two images is verified. CONCLUSIONS A novel optical device is demonstrated to have the potential for field expansion technology in a variety of conditions. The devices may be inexpensive and can be constructed in a cosmetically acceptable format.
منابع مشابه
Tunnel Vision Prismatic Field Expansion: Challenges and Requirements.
PURPOSE No prismatic solution for peripheral field loss (PFL) has gained widespread acceptance. Field extended by prisms has a corresponding optical scotoma at the prism apices. True expansion can be achieved when each eye is given a different view (through visual confusion). We analyze the effects of apical scotomas and binocular visual confusion in different designs to identify constraints on...
متن کاملHigh-Power Prismatic Devices for Oblique Peripheral Prisms
PURPOSE Horizontal peripheral prisms for hemianopia provide field expansion above and below the horizontal meridian; however, there is a vertical gap leaving the central area (important for driving) without expansion. In the oblique design, tilting the bases of both prism segments toward the horizontal meridian moves the field expansion area vertically and centrally (closing the central gap) wh...
متن کاملTreating Hemianopia Using Prisms to Create Peripheral Diplopia
Most optical aids for hemianopia provide only field relocation while field expansion is the desired effect and thus, these aids are rarely successful. This paper describes a novel method for prism correction of hemianopia that provides actual field expansion in a convenient and functional format. To expand the upper quadrant of the field, a high power prism segment (30-40 PD) is placed base-out...
متن کاملImpact of high power and angle of incidence on prism corrections for visual field loss.
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results ...
متن کاملADOBE TECHNICAL REPORT Light-Field Capture by Multiplexing in the Frequency Domain
In previous works light-field capture has been analyzed in spatio-angular representation. A light-field camera samples the optical signal within a single photograph by multiplexing the 4D radiance onto the physical 2D surface of the sensor. In this paper we develop a theory of multiplexing the radiance in the frequency domain by optically mixing different spatial and angular frequency component...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 94 8 شماره
صفحات -
تاریخ انتشار 2017