A Study on Leaching Behavior of Na, Ca and K Using Column Leach Test

نویسنده

  • Gupta
چکیده

Column leach test has been performed to examine the behavior of leaching of sodium, calcium and potassium in landfills. In the column leach apparatus, two different layers of contaminated and uncontaminated soils of different height ratios (ratio of depth of contaminated soil to the depth of uncontaminated soil) are taken. Water is poured from an overhead tank at a particular flowrate to the inlet of the soil column for a certain ponding depth over the contaminated soil. Subsequent infiltration causes leaching and the leachates are collected from the bottom of the column. The concentrations of Na, Ca and K in the leachate are measured using flame photometry. The experiments are further extended by changing the rates of flow from the overhead tank to the inlet of the column in achieving the same ponding depth. The experiments are performed for different scenarios in which the height ratios are altered and the variations of concentrations of Na, Ca, and K are observed. The study brings an estimation of leaching in landfill sites for different heights and precipitation intensity where a ponding depth is maintained over the landfill. It has been observed that the leaching behavior of Na, Ca, and K are not similar. Calcium exhibits highest amount of leaching compared to Sodium and Potassium under similar experimental conditions. Keywords—Column leaching, flow rate, uncontaminated soil, contaminated soil, concentration, height ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Column leaching experiments on saline soils of different textures in Sistan plain

Salinization is the main characteristic of soils in arid and semi-arid regions which reduce the agricultural potential ofirrigated lands. Therefore, soil reclamation as well as determination of the leaching requirement for salt control is veryimportant for better plant growth. In this study, the effects of leaching on saline soils of Sistan region, southeast of Iranwere examined using unsaturat...

متن کامل

Effects of Pregnant Leach Solution Temperature on the Permeability of Gravelly Drainage Layer of Heap Leaching Structures

In copper heap leaching structures, the ore is leached by an acidic solution. After dissolving the ore mineral, the heap is drained off in the acidic solution using a drainage system (consisting of a network of perforated polyethylene pipes and gravelly drainage layers) and is, then, transferred to the leaching plant for copper extraction where the copper is extracted and the remaining solution...

متن کامل

Evaluation of Leaching Protocols for Testing of High-Carbon Coal Fly Ash–Soil Mixtures

Beneficial reuse of coal combustion byproducts, e.g., in highway construction, requires an evaluation of metal leaching potential. Metal leaching from high-carbon fly ash in soil mixes typical of highway embankment construction was evaluated using different soil-fly ash mixtures and three common leaching tests: the water leach test (WLT), the Toxicity Characteristic Leaching Procedure (TCLP), a...

متن کامل

Experimental and numerical analysis of metal leaching from fly ash-amended highway bases.

A study was conducted to evaluate the leaching potential of unpaved road materials (URM) mixed with lime activated high carbon fly ashes and to evaluate groundwater impacts of barium, boron, copper, and zinc leaching. This objective was met by a combination of batch water leach tests, column leach tests, and computer modeling. The laboratory tests were conducted on soil alone, fly ash alone, an...

متن کامل

Kinetics of chemical leaching of chalcocite from low-grade copper ore: size-distribution behavior

Kinetics of the chemical leaching of chalcocite from a low-grade copper ore in a ferric sulfate medium was investigated using the constrained least square optimization technique. The experiments were carried out for different particle sizes in both the reactor and column at constant Eh, pH, and temperature. The leaching rate increased with increase in the temperature. About 50% of the Cu recove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012