OPTICAL PLANAR WAVEGUIDE SENSOR BASED ON (Yb,Nb):RTP/RTP(001) SYSTEM FOR THE ESTIMATION OF METAL COATED CELLS

نویسنده

  • M. A. Butt
چکیده

In this work, we demonstrated metal tagged cell counting based on planar waveguide with the help of a visible light at 633 nm with TM polarization and calculated the output power in relation with the density of cells placed on the waveguide.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Channel waveguides and Mach-Zehnder structures on RbTiOPO4 by Cs ion exchange

Cs ion exchange in RbTiOPO4 and (Yb,Nb):RTP/RTP(001) has been used to locally increase the refractive indices for waveguide circuit fabrication. Ti masks were fabricated on RTP samples by conventional photolithography. Cs exchange was done using a CsNO3 melt at 698 K during 2 h. Elemental analysis confirms an Cs profile with a variable depth. Apparently the Cs exchange is disfavored in the dope...

متن کامل

بررسی ابتدا به ساکن ویژگی‌های فیزیکی دو تک‌بلور KTP و RTP

In this work,the physical properties of  KTP and RTP single-crystals have been investigated by performing accurate total energy calculations in the framework of density functional theory by using the full-potential linearized augmented plane wave method. The effects of Rb substitution on structural, electronic and optical properties of KTP are discussed. The structural properties have been calc...

متن کامل

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

Comparison of three different phosphorescent methodologies in solution for the analysis of naphazoline in pharmaceutical preparations.

We present results from a comparative study of three proposed phosphorimetric methods for determination of naphazoline (NPZ) in solution. The first method is based on use of micelles to stabilize phosphorescence signals in solutions at room temperature (MS-RTP). The second is based on the use of a heavy atom salt and sodium sulfite as an oxygen scavenger to obtain room-temperature phosphorescen...

متن کامل

Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 9. Incorporation of planar waveguide technology.

Incorporation of planar waveguide technology into a spectroelectrochemical sensor is described. In this sensor design, a potassium ion-exchanged BK7 glass waveguide was over-coated with a thin film of indium tin oxide (ITO) that served as an optically transparent electrode. A chemically selective film was spin-coated on top of the ITO film. The sensor supported five optical modes at 442 nm and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016