BACKGROUND Oral fluid is currently being evaluated as an alternative matrix for monitoring illicit drugs in federally mandated workplace drug testing, for addiction treatment programs, and for driving under the influence testing. The sensitivity, specificity, and efficiency of the Cozart Microplate EIA Cocaine Oral Fluid Kit (COC ELISA) were determined by comparison with gas chromatography-mass spectrometry (GC/MS) results at screening and confirmation cutoffs proposed in the US and UK. METHOD Oral fluid was collected by expectoration after citric acid candy stimulation or with Salivette neutral cotton swabs or Salivette citric acid-treated cotton swabs before and after cocaine (COC) administration. Specimens (n = 1468) were analyzed with the COC ELISA for screening and with solid-phase extraction followed by GC/MS for confirmation. Three screening cutoffs (10, 20, and 30 microg/L) and four GC/MS cutoffs (2.5, 8, 10, and 15 microg/L COC, benzoylecgonine, and/or ecgonine methyl ester) were evaluated. GC/MS limit of quantification was 2.5 micro g/L for all analytes. RESULTS COC ELISA interassay imprecision (CV; n = 19) was 16% at 16.7 microg/L and 12% at 81.8 microg/L. With the 2.5, 8, 10, and 15 microg/L GC/MS cutoffs, 59.0%, 54.7%, 52.7%, and 48.7% of the oral fluid specimens were positive, respectively. Sensitivity, specificity, and efficiency were 92.2%, 84.7%, and 88.8%, respectively, for the suggested Substance Abuse and Mental Health Services Administration (SAMHSA) cutoffs and 90.2%, 89.2%, and 89.7% for cutoffs currently used in the UK. CONCLUSIONS COC ELISA had suitable sensitivity, specificity, and efficiency for identifying COC exposure at both the proposed SAMHSA and UK cutoffs. Sensitivity, specificity, and efficiency were >84% for both cutoffs, but 92 additional true-positive samples were identified with the SAMHSA cutoffs.
منابع مشابه
Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart Opiate Microplate EIA and GC-MS following controlled codeine administration.
Oral fluid specimens (N = 1406) were collected from 19 subjects prior to and up to 72 h following controlled administration of oral codeine. Volunteers provided informed consent to participate in this National Institute on Drug Abuse Institutional Review Board-approved protocol. A modification of Cozart Microplate Opiate EIA Oral Fluid Kit (Opiate ELISA), employing codeine calibrators, was used...
متن کاملValidation of the Cozart Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid.
The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples w...
متن کاملAnalytical evaluation of four on-site oral fluid drug testing devices.
The use of oral fluid (OF) as an alternative matrix for the detection of drugs of abuse has increased over the last decade, leading to the need for a rapid, simple, and reliable on-site OF testing device. Four on-site OF drug testing devices (Dräger DrugTest 5000, Cozart DDS, Mavand Rapid STAT, and Innovacon OrAlert) were evaluated on 408 volunteers at drug treatment centers. UPLC-MS-MS results...
متن کاملOn-site test for cannabinoids in oral fluid.
BACKGROUND Oral fluid (OF) testing offers noninvasive sample collection for on-site drug testing; however, to date, test performance for Δ(9)-tetrahydrocannabinol (THC) detection has had unacceptable diagnostic sensitivity. On-site tests must accurately identify cannabis exposure because this drug accounts for the highest prevalence in workplace drug testing and driving under the influence of d...
متن کاملDevelopment and validation of the Cozart DDS oral fluid collection device.
The testing of oral fluid for drugs of abuse has increased significantly over recent years and is now commonplace in drug rehabilitation clinics, the workplace, prisons and custody suites. The global problem of identifying drugged drivers has also led to an increase in oral fluid testing at the roadside. The main requirements for the implementation of roadside drug testing are a rapid sample co...