BACKGROUND Intracapsular femoral neck fractures are associated with high rates of nonunion. We aimed to identify risk factors for nonunion in patients with both displaced and nondisplaced intracapsular femoral neck fractures treated with three 7-mm parallel cannulated screws, placed in either a triangle or an inverted triangle configuration, using failure of fixation as the primary outcome. METHODS Clinical and radiographic data for patients with intracapsular femoral neck fractures treated with either triangle fixation (one proximal screw and two distal screws) or inverted triangle fixation (two proximal screws and one distal screw), between January 1, 2000, and July 30, 2009, were analyzed. RESULTS A total of 202 patients, seventy-six men and 126 women with an average age (and standard deviation) of 64.53 ± 15.81 years (range, nineteen to ninety-three years), were included in the analysis. Union occurred in 158 patients, and nonunion occurred in forty-four. There were no differences between the union and nonunion groups with respect to age, sex, fracture side, fracture angle, fracture level, or estimated bone density. There were significant differences in fracture type, fixation configuration, reduction quality, and screw-tip subchondral purchase between patients with and without union. The estimated odds ratio for fracture nonunion was 2.93 (95% confidence interval [CI], 1.08, 7.96) in subjects with displaced fractures compared with those without displaced fractures (p = 0.035), 18.92 (95% CI, 1.91, 187.09) in subjects with borderline and unacceptable reduction compared with those with anatomic reduction (p = 0.012), and 2.92 (95% CI, 1.27, 6.69) for internal fixation with a triangle configuration compared with fixation with an inverted triangle configuration (p = 0.010). CONCLUSIONS Screw fixation with a triangle configuration, a displaced fracture, and poor reduction are risk factors for nonunion in intracapsular femoral neck fractures treated with fixation with multiple screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osteosynthesis of Femoral Neck Fractures: Two or Three Screws?

OBJECTIVES To evaluate the efficacy of osteosynthesis on femoral neck fractures using two instead of three screws. METHODS Thirty-nine fractures were retrospectively evaluated, divided into groups in which two screws were used in parallel (n = 28) or three screws (n =11) in an inverted triangle configuration (in accordance with the AO technique). The patients were then followed up until reach...

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Metformin Prevents Nonunion after Three-Cannulated-Screw Fixation in Displaced Femoral Neck Fractures: A Retrospective Study

Patients aged from 40 to 60 with displaced fractures of the femoral neck (Garden III or IV) who received fixation with three cannulated screws from January 2005 to December 2012 were evaluated retrospectively for the development of nonunion. Plasma HbA1C, a marker for long-term plasma glucose level, anti-T2DM medication, and other potential risk factors were recorded for the purpose of this stu...

متن کامل

Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures

In this research, biomechanical behaviors of five different configurations of screws used for stabilization of femoral neck fracture under axial loading have been examined, and which configuration is best has been investigated. A point cloud was obtained after scanning the human femoral model with a three dimensional (3-D) scanner, and this point cloud was converted to a 3-D femoral model by Ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 95 1  شماره 

صفحات  -

تاریخ انتشار 2013