Structural model of the mitral valve included in a cardiovascular closed loop model Static and dynamic validation

نویسنده

  • S. Paeme
چکیده

A minimal cardiovascular system (CVS) model including mitral valve dynamics has been previously validated in silico. It accounts for valve dynamics using a second order differential equation to simulate the physiological opening valve law. This second order equation is based on output heart signals and is really difficult to bind with anatomical or physiological parameters, making this model difficult to interpret and to particularise to pathological situations. On the other hand, a simple non-linear rotational spring model implemented to model the motion of mitral valve, located between the left atrium and ventricle has been validated on a literature dataset. A measured pressure difference curve was used as the input into the model, which represents an applied torque to the valve chords. Various damping and hysteresis states were investigated to find a model that best matches reported animal data of chord movement during a heartbeat. This model is based on simple physiological behavior modeling, defining parameters linked with physiological or anatomical data. This research describes a new closed-loop CVS model corresponding to the integration of the simple non-linear rotational spring model to describe the progressive aperture of the mitral valve in the minimal cardiovascular system closed loop model. This new model is proved to fit static and dynamic heart behaviour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY

BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...

متن کامل

Developing a Mixed Integer Quadratic Programing Model with Integer Numbers for Designing a Dynamic closed-loop Logistics Network

Logistics Network Design includes network configuration decisions having long-standing influences on other tactical and operational decisions. Recently, regarding environmental issues and customer awareness and global warming closed-loop supply chain network design is taken into consideration. The proposed network for the integrated forward and reverse logistics is developed by formulating a cy...

متن کامل

Considering Pricing Problem in a Dynamic and Integrated Design of Sustainable Closed-loop Supply Chain Network

Flexible and dynamic supply chain network design problem has been studied by many researchers during past years. Since integration of short-term and long-term decisions in strategic planning leads to more reliable plans, in this paper a multi-objective model for a sustainable closed-loop supply chain network design problem is proposed. The planning horizon of this model contains multiple strate...

متن کامل

A Multi-Objective Fuzzy Approach to Closed-Loop Supply Chain Network Design with Regard to Dynamic Pricing

During the last decade, reverse logistics networks received a considerable attention due to economic importance and environmental regulations and customer awareness. Integration of leading and reverse logistics networks during logistical network design is one of the most important factors in supply chain. In this research, an Integer Linear Programming model is presented to design a multi-layer...

متن کامل

Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

BACKGROUND Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. METHODS A cardiovascular and circulatory syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012