Endocardial silicone lead wear: description of tribological phenomena on the basis of microscopic examination of removed leads. Preliminary report.

نویسندگان

  • Barbara Małecka
  • Andrzej Ząbek
  • Andrzej Ciaś
  • Janusz Stępiński
  • Andrzej Kutarski
  • Jacek Rońda
  • Jacek Lelakowski
  • Janusz Małecki
چکیده

BACKGROUND The passage of a lead in tissues and in the cardiovascular system depends on the implantation technique. The structure of the leads, which is a combination of two or more materials, triggers their wear. Breakage of the external pacemaker (PM) lead insulation causes unsealing of the lead and exposure of its internal spaces, which can be the anchor of lead-dependent infective endocarditis (LDIE). In the case of implantable cardioverter-defibrillator (ICD) leads, damage to external insulation isthe cause of externalisation of the cable. AIM To describe endocardial lead abrasion as a tribological phenomenon resulting from rubbing the leads against each other in the mechanism of polymer on polymer friction, and other mechanisms associated with lead structure i.e. polymer on metal friction. METHODS Twenty-two leads were extracted from ten patients (three women) aged 66.5 ± 13.4 years. In all cases, the reason for lead removal was infection — in 80% LDIE. The PM (one ICD) two- and three-lead systems, all with silicone insulation, were aged 3–25, mean 8.3 years. The destroyed polymer insulation was examined by optical and scanning electron microscopy. The site of damage was defined as the length of the lead from its distal end. This lead segment motion was analysed on chest scopy performed prior to the removal procedure. In this way, three sites of lead damage were distinguished: intracardiac, intravenous, and intrapocket. Tribological wear was observed on the polymer-metal interface and between the leads. The following characteristics were recorded: the type of PM or ICD system in which the extracted leads worked, the lead dwell time,and the lead model. RESULTS Scanning electron examinations showed that in all cases lead insulation had undergone tribological failure. In all samples, the image of fatigue wear was recorded. In all examined places, we found evidence that adhesive wear was present with the transfer of material to the edges of friction zones and/or to friction partners. In 80% of the patients with LDIE, a total breakage of insulation and abrasive wear was observed, especially when a lead cyclically bent and rubbed against another lead. Abrasive wear was the cause of lead unsealing at sites of strong lead bending, in the right atrium near the tricuspid valve. CONCLUSIONS Acknowledging the tribological mechanism may connect the commonly known crush syndrome with lead abrasion in the cardiac implantable device pocket and in the heart cavity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INFLUENCE OF MECHANICAL ALLOYING AND LEAD CONTENT ON MICROSTRUCTURE, HARDNESS AND TRIBOLOGICAL BEHAVIOR OF 6061 ALUMINIUM ALLOYS

In the present work, one batch of prealloyed 6061Al powder was processed by mixing and another one was ball milled with varying amount of lead content (0-15 vol. %). These powders were compacted at 300MPa and sintered at 590˚C under N2. The instrumented hardness and the young’s modulus of as-sintered 6061Al-Pb alloys were examined as a function of lead content and processing route. The we...

متن کامل

Tribological Behaviour of Fe-Al Intermetallic Compound Coated Carbon Tool Steel

The use of Fe-Al intermetallic compound coatings has been investigated in order to improve the tribological behaviour of carbon tool steel. The coatings were formed by a pack cementation process and subsequently diffusion annealing at 900˚C in an argon controlled atmosphere. The optimum diffusion time was selected on the basis of optimum thickness and tribological behaviour.&#10The microstructu...

متن کامل

Tribological Behaviour of Fe-Al Intermetallic Compound Coated Carbon Tool Steel

The use of Fe-Al intermetallic compound coatings has been investigated in order to improve the tribological behaviour of carbon tool steel. The coatings were formed by a pack cementation process and subsequently diffusion annealing at 900˚C in an argon controlled atmosphere. The optimum diffusion time was selected on the basis of optimum thickness and tribological behaviour. The microstructure...

متن کامل

The Effect of Carbides Morphology on Tribological Behaviour of Ni-Hard 4 Cast Irons

In this research the effect of volume and morphology of eutectic carbides on tribological behaviour of Ni-Hard 4 cast irons have been investigated. Therefore, as a result of the fact that the carbon content effects the carbides morphology of Ni-hard cast irons, the chemical compositions of five different specimens were kept constant with the exception of the carbon content, which was varied fro...

متن کامل

The Effect of Carbides Morphology on Tribological Behaviour of Ni-Hard 4 Cast Irons

In this research the effect of volume and morphology of eutectic carbides on tribological behaviour of Ni-Hard 4 cast irons have been investigated. Therefore, as a result of the fact that the carbon content effects the carbides morphology of Ni-hard cast irons, the chemical compositions of five different specimens were kept constant with the exception of the carbon content, which was varied fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kardiologia polska

دوره 72 10  شماره 

صفحات  -

تاریخ انتشار 2014