Aligning 2-D Cardiac MR Images in 3-D Space using Normalized Mutual Information

نویسندگان

  • Joel Barajas
  • Karla L Caballero
  • Jaume Garcia-Barnes
  • Francesc Carreras
  • Sandra Pujadas
  • Petia Radeva
چکیده

Cardiac Magnetic Resonance images offer the opportunity to study the heart in detail. One of the main issues in its modelling is to create an accurate 3-D reconstruction of the left ventricle from 2-D views. A first step to achieve this goal is the correct registration among the different image planes due to patient movements. In this article, we present an accurate method to correct displacement artifacts using the Normalized Mutual Information. Here, the image views are treated as planes in order to diminish the approximation error caused by the association of a certain thickness, and moved simultaneously to avoid any kind of bias in the alignment process. This method has been validated using real and syntectic plane displacements, yielding promising results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of Misalignment Artifacts Among 2-D Cardiac MR Images in 3-D Space

Cardiac Magnetic Resonance images offer the opportunity to study the heart in detail. One of the main issues in its modelling is to create an accurate 3-D reconstruction of the left ventricle from 2-D views. A first step to achieve this goal is the correct registration among the different image planes due to patient movements. In this article, we present an accurate method to correct displaceme...

متن کامل

Optimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps

Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...

متن کامل

Normalized Measures of Mutual Information with General Definitions of Entropy for Multimodal Image Registration

Mutual information (MI) was introduced for use in multimodal image registration over a decade ago [1,2,3,4]. The MI between two images is based on their marginal and joint/conditional entropies. The most common versions of entropy used to compute MI are the Shannon and differential entropies; however, many other definitions of entropy have been proposed as competitors. In this article, we show ...

متن کامل

Multi-channel Mutual Information Using Scale Space

We propose a new voxel similarity measure which utilises local image structure as well intensity information. Gaussian scale space derivatives are used to provide the structural information. Each derivative is assigned to an information channel of higher dimensional form of normalised mutual information. We illustrate the behaviour of the measure for a simulated signal and 2D medical brain imag...

متن کامل

Non-rigid Registration of T1 MR Images Constrained with Fractional Anisotropic (FA) Maps

Introduction Conventional images, such as T1 weighted (T1W) or T2 weighted (T2W) MR images, provide basic contrast information between gray matter, white matter, and cerebro-spinal fluid. However, those images are limited because they provide little contrast between distinct white matter structures. Diffusion tensor imaging (DTI) is a complementary tool that provides information on the orientat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006