Experimental and model investigations of bleaching and saturation of fluorescence in flow cytometry.

نویسندگان

  • R M Doornbos
  • B G de Grooth
  • J Greve
چکیده

We investigated the fluorescence emission from three fluorophores commonly used for labeling cells in flow cytometry. We have demonstrated that the fluorescence emission from cells labeled with fluorescein-isothiocyanate (FITC), phycoerythrin (PE), and allophycocyanin (APC) is considerably saturated and bleached in standard flow cytometric conditions. Therefore, for optimization of fluorescence detection in a flow cytometer, it is important to know the emission kinetics in detail. We made a mathematical model of the optical processes involved: absorption, fluorescence emission, nonradiative decay, photodestruction, and triplet state occupation. The validity of the model was experimentally tested with a set of averaged fluorescence pulses, measured in a large range of intensities and illumination times. The fluorescence of APC could be completely described by the model and produced the following rate constants: photodestruction rate kb1 = 6 x 10(3) s(-1), triplet state population rate k12 = 2 x 10(5) s(-1), and depopulation rate k20 = 5 x 10(4) s(-1). The fluorescence kinetics of FITC- and PE-labeled cells could not be fitted with only three parameters over the entire range, indicating that other optical processes are involved. We used the model to determine the sensitivity of our flow cytometer and to calculate the optimum conditions for the detection of APC. The results show that in principle a single APC molecule on a cell can be detected in the presence of background, i.e., autofluorescence and Raman scattering by water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P-6: Flow Cytometry: Assessment of Protamine Deficiency by CMA3 Staining and Apoptotic Bodies

Background: Chromomycin A3 (CMA3) staining, with the slide method or fluorescence microscopy, is widely used for indirect assessment of protamine deficiency in a semen sample. Flow cytometry is the most suitable tool which to improve assessment accuracy, both in terms of statistical analysis and to prevent observer variation. This study provides a simple procedure to account for merocyanine 540...

متن کامل

Unsteady Numerical Investigations of Flow and Heat Transfer Characteristics of Nanofluids in a Confined Jet Using Two-Phase Mixture Model

The development of high-performance thermal systems has increased interest in heat transfer enhancement techniques. The application of additives to heat transfer liquids is one of the noticeable effort to enhance heat transfer. In this paper two-dimensional unsteady incompressible nanofluid flow in a confined jet at the laminar flow regime is numerically investigated. The Mixture model is consi...

متن کامل

Experimental and Numerical Pore Scale Study of Residual Gas Saturation in Water/Gas Imbibition Phenomena

Residual gas saturation is one of the most important parameter in determining recovery factor of water-drive gas reservoir. Visual observation of processes occurring at the pore level in micromodels can give an insight to fluid displacements at the larger scale and also help the interpretation of production performance at reservoir scale. In this study experimental tests in a glass micromod...

متن کامل

Flow Cytometry: A New Approach for Indirect Assessment of Sperm Protamine Deficiency

Background Flow cytometry (FCM) has been extensively used to study mammalian sperm in the areas of clinical andrology and reproductive toxicology. FCM provides a powerful advantage over microscopy technique in terms of rapid accurate and reproducible technology for the quantification of various cell characteristics including chromatin status. During spermiogenesis histones are replaced by prota...

متن کامل

Modeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus

In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 1997