Axial length estimation error caused by hidden double-peak on partial coherence interferometry in an eye with epiretinal membrane: a case report
نویسندگان
چکیده
Here we report a patient in whom there was a myopic shift after combined cataract surgery and pars plana vitrectomy against the epiretinal membrane, related to axial measurement estimation error caused by a hidden double-peak appearance on partial coherence interferometry measurement. A 52-year-old female presented with epiretinal membrane and underwent combined cataract surgery and pars plana vitrectomy. Axial length was measured with partial coherence interferometry. Although the signal curve in the summary display showed a single peak, a 1.6 diopter myopic shift occurred. Viewed retrospectively, six of 20 individual signal curves showed a double peak. Most of them showed a higher anterior peak, with only one having a higher posterior peak. The other 14 curves showed a single peak at a similar distance to an anterior peak. The anterior peak appeared to be derived from the epiretinal membrane. The possibility of a double peak should always be considered in patients with epiretinal membrane even if the summary display of the partial coherence interferometry measurement shows a single peak. Checking all signal curves would reduce the risk of missing a hidden double peak.
منابع مشابه
Immersion A-scan compared with partial coherence interferometry: outcomes analysis.
PURPOSE To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING Oregon Eye Institute, Eugene, Oregon, USA. METHODS Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound ...
متن کاملEstimation of Earthquake Damage Through Radar Interferometry (Case study: Bam 2003 Earthquake)
The estimate of the damage caused by the earthquake and other natural disasters in the first days after the occurrence of these events can provide a quick damages assessment and help to manage the crisis. Several methods are available to investigate the extent of earthquake’s damage. Optical remote sensing, photogrammetric methods (UAVs and LIDARs), radar interferometry (InSAR) and field observ...
متن کاملPartial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes
PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements...
متن کاملIntraocular Lens Power Estimation in Combined Phacoemulsification and Pars Plana Vitrectomy in Eyes with Epiretinal Membranes: A Case-Control Study
PURPOSE To evaluate the accuracy of postoperative refractive outcomes of combined phacovitrectomy for epiretinal membrane (ERM) in comparison to cataract surgery alone. MATERIALS AND METHODS Thirty-nine eyes that underwent combined phacovitrectomy with intraocular lens (IOL) implantation for cataract and ERM (combined surgery group) and 39 eyes that received phacoemulsification for cataract (...
متن کاملErrors associated with IOLMaster biometry as a function of internal ocular dimensions.
PURPOSE To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). METHODS Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20mm to 3...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -