Application of voxel phantoms to study the influence of the heterogeneous distribution of actinides in lungs on in vivo counting using animal experiments

نویسندگان

  • S. LAMART
  • N. PIERRAT
  • S. RATEAU
  • E. ROUIT
  • L. DE CARLAN
  • N. DUDOIGNON
  • M. BOTTLAENDER
  • A. VAN DER MEEREN
  • D. FRANCK
چکیده

As part of the improvement of calibration techniques for in vivo counting, the Laboratory of Internal Dose Assessment of IRSN has developed a computer tool, “OEDIPE”, to model internal contamination in voxel phantoms, to simulate in vivo counting and to calculate internal dose. This software was used to model the real distribution of activity in the lungs of a baboon analyzed in the Laboratory of Radiotoxicology of CEA. This experiment provided the opportunity to study the influence of the heterogeneity of lung retention on the in vivo counting and to quantify its effect on the assessment of activity by comparison with a simulated homogeneous retention of the same total activity. The results show that the numerical simulation can be a relevant tool to reveal the heterogeneity of lung retention, allowing a determination of calibration factors adapted to heterogeneous contaminations that would be impossible by standard calibration with physical anthropomorphic phantoms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

Design of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements

Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...

متن کامل

Hybrid Phantom Applications to Nuclear Medicine

Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...

متن کامل

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

متن کامل

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...