Random Excitation by Optimized Pulse Inversion in Contrast Harmonic Imaging

نویسندگان

  • Sébastien Ménigot
  • Jean-Marc Girault
چکیده

Over the past twenty years, in ultrasound contrast imaging, new physiological information are obtained by the detection of non-linearities generated by the microbubbles. One of the most used techniques is the pulse inversion imaging. The usual command of this system is a fixed-frequency sinus wave. An optimal choice of this command requires the knowledge of the transducer and of the medium to obtain the best contrast-to-tissue ratio. However, these information are experimentally inaccessible. Our goal is to seek the command which maximizes the contrastto-tissue ratio. Among several noises, we identified the one which maximized the contrast-to-tissue ratio. A new suboptimal control was made from the parameters of a nonlinear autoregressive filter and from suboptimal noise. The contrast-to-tissue ratio was then iteratively optimized by the method of Nelder-Mead which adjusted the filter parameters. The gain compared to the case in which we used at the optimal frequency can reach about 1 dB and 5 dB in comparison to the center frequency of the transducer. By adding a closed loop, the system automatically proposes the optimal command without any a priori knowledge of the system or of the medium explored and without any hypothesis about the shape of the command.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Optimization of Chirp Setting Parameters in Medical Ultrasound Contrast Imaging

Medical ultrasound contrast imaging is a powerful modality undergoing successive developments in the last decade to date. Lately, pulse inversion has been used in both ultrasound tissue harmonic and contrast imaging. However, there was a tradeoff between resolution and penetration. Chirp excitations partially solved the tradeoff, but the chirp setting parameters were not optimized. The present ...

متن کامل

Myocardial contrast echocardiography yields best accuracy using quantitative analysis of digital data from pulse inversion technique: comparison with second harmonic imaging and harmonic power Doppler during simultaneous dipyridamole stress SPECT studies.

AIMS This prospective study assesses the (1) feasibility of quantifying ultrasound myocardial perfusion studies based on the densitometric analysis of digital data and the (2) comparison of pulse inversion, second harmonic and harmonic power Doppler modalities with SPECT. METHODS AND RESULTS Twenty-three patients with suspected ischaemic heart disease had i.v. injections of Tc-Sestamibi and O...

متن کامل

Pulse Inversion Imaging of Liver with Microbubble Contrast: Improved Characterization of Tumoral Vasculature in Focal Hepatic Lesions

The challenge presented to ultrasound imaging technology by the advent of microbubble contrast agents is to create a method that detects the echoes from bubbles in preference to the echoes from tissue. Recent progress in ultrasonography is represented by the development of harmonic and pulse inversion imaging (Fig. 1, 2). Pulse inversion imaging is a newly developed one, which uses the full ban...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Comparison of contrast-enhanced fundamental imaging, second-harmonic imaging, and pulse-inversion harmonic imaging.

RATIONALE AND OBJECTIVES To investigate the feasibility of recent contrast-specific ultrasound techniques in depicting vascular flow and the effects of changing the output power of the transducer and insonation mode on contrast enhancement, the authors performed an experimental study with a flow phantom. METHODS While changing the mechanical index and the sound insonation mode (continuous and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012