Acceleration/ejection time ratio in the fetal pulmonary artery predicts fetal lung maturity.

نویسندگان

  • Humberto Azpurua
  • Errol R Norwitz
  • Katherine H Campbell
  • Edmund F Funai
  • Christian M Pettker
  • Michael Kleine
  • Mert O Bahtiyar
  • Herbert Malkus
  • Joshua A Copel
  • Stephen F Thung
چکیده

OBJECTIVE The aim of this study was to determine whether sonographic fetal pulmonary artery flow velocity waveforms correlate with amniotic fluid biomarkers of fetal lung maturity. STUDY DESIGN We studied women with singleton pregnancies undergoing clinically indicated amniocentesis for fetal lung maturity at Yale-New Haven Hospital. Fetal pulmonary artery flow velocity measurements, including systolic/diastolic ratio, pulsatility index, resistance index, and acceleration-time/ejection-time ratio were obtained using spectral Doppler ultrasound. Pearson's correlation coefficient was used to determine the association between fetal pulmonary artery flow velocity parameters and the lecithin/sphingomyelin ratio. RESULTS Twenty-nine subjects met study criteria. The acceleration-time/ejection-time ratio was inversely correlated with the lecithin/sphingomyelin ratio (r = -0.76; P < or = .001). This relationship was maintained after controlling for potential confounders. Other fetal pulmonary artery flow velocity measurements were not associated with the lecithin/sphingomyelin ratio. CONCLUSION There is an inverse correlation between the acceleration-time/ejection-time ratio in the fetal pulmonary artery and the amniotic fluid lecithin/sphingomyelin ratio. This suggests that ultrasound evaluation of fetal pulmonary artery blood flow may be a promising new noninvasive technique to evaluate fetal lung maturity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does corticosteroid therapy impact fetal pulmonary artery blood flow in women at risk for preterm birth?

AIM Maternal corticosteroid administration in pregnancy is known to enhance fetal lung maturity in at risk fetuses. The aim of this study was to test the hypothesis that corticosteroid therapy alters fetal pulmonary blood flow in pregnancies at risk for preterm birth (PTB). MATERIAL AND METHODS We prospectively evaluated main fetal pulmonary artery (MPA) blood flow in pregnant women at risk f...

متن کامل

Intraobserver variation in Doppler ultrasound assessment of pulmonary artery pressure.

Intraobserver variation associated with the non-invasive assessment of pulmonary artery pressure (PAP), using measurement of pulmonary artery Doppler derived systolic time intervals, was investigated. Forty pairs of independent ultrasound examinations of the pulmonary artery were performed by a single observer in 20 preterm infants, median gestation 27 weeks (range 24-31 weeks). Median age at s...

متن کامل

Pulmonary artery pressure: early predictor of chronic lung disease in preterm infants.

AIM To determine if pulmonary artery pressure (PAP) in ventilated preterm infants is independently associated with the development of chronic lung disease (CLD) and whether early assessment has any prognostic value. METHODS Two cohorts (development n = 55; and validation n = 28) of preterm infants were studied at 24 hours of age. PAP was assessed non-invasively using its inverse correlation w...

متن کامل

Raised pulmonary artery pressure in very low birthweight infants requiring supplemental oxygen at 36 weeks after conception.

This study aimed to investigate the changes in pulmonary artery pressure in infants with chronic lung disease who then developed prolonged oxygen dependency. The time to peak velocity: right ventricular ejection time (TPV:RVET) ratio calculated from the Doppler waveform, which correlates negatively with pulmonary artery pressure, was used. Thirty four infants with chronic lung disease were stud...

متن کامل

Doppler flow velocity waveforms of human fetal ductus arteriosus and branch pulmonary artery.

Doppler waveforms of the human fetal ductus arteriosus and the branch pulmonary artery are distinct in their shape and might reflect fetal cardiovascular hemodynamics and vessel wall characteristics. The waveform of ductus arteriosus had two peaks, a higher one in systole and a lower one in diastole. Both peaks had slow acceleration and deceleration and looked like two narrow base isosceles tri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of obstetrics and gynecology

دوره 203 1  شماره 

صفحات  -

تاریخ انتشار 2010