Development and tests of fast 1-MA linear transformer driver stages
نویسندگان
چکیده
A.A. Kim, M.G. Mazarakis, V.A. Sinebryukhov, B.M. Kovalchuk, V.A. Visir, S. N. Volkov, F. Bayol, A.N. Bastrikov, V. G. Durakov, S. V. Frolov, V.M. Alexeenko, D.H. McDaniel, W. E. Fowler, K. LeChien, C. Olson, W.A. Stygar, K.W. Struve, J. Porter, and R.M. Gilgenbach Institute of High Current Electronics, Russian Academy of Sciences, Tomsk 634055, Russia Sandia National Laboratories, Albuquerque, New Mexico 87185, USA International Technologies for High Pulsed Power, Thégra 46500, France University of Michigan, Ann Arbor, Michigan 48109-2104, USA (Received 4 March 2009; published 29 May 2009)
منابع مشابه
A Fast Method for Calculation of Transformers Leakage Reactance Using Energy Technique
Energy technique procedure for computing the leakage reactance in transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using practic...
متن کاملFast Scr Thyratron Driver
As part of an improvement project on the linear accelerator at SLAC, it was necessary to replace the original thyratron trigger generator, which consisted of two chassis, two vacuum tubes, and a small thyratron. All solid-state, fast rise, and high voltage thyratron drivers, therefore, have been developed and built for the 244 klystron modulators. The rack mounted, single chassis driver employs...
متن کاملDevelopment of Ion Sources for Komac
A Duoplasmatron ion source for the KOrea Multipurpose Accelerator Complex (KOMAC) linear accelerator has been constructed. High voltage tests up to 50 kV have been successfully completed. Hydrogen beam currents of up to 20 mA have been extracted at 30 kV extraction voltage. This source has shown a low normalized emittance of 0.5 π mm mrad from 90 % beam current and proton fraction over 50%. Hig...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملDevelopment of the Pulse Transformer for Nlc Klystron Pulse Modulator
We have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and core size. After making a tradeoff ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -