Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients.

نویسندگان

  • M R Grubb
  • J Carpenter
  • J A Crowe
  • J Teoh
  • N Marlow
  • C Ward
  • C Mann
  • D Sharkey
  • B R Hayes-Gill
چکیده

Around 5%-10% of newborn babies require some form of resuscitation at birth and heart rate (HR) is the best guide of efficacy. We report the development and first trial of a device that continuously monitors neonatal HR, with a view to deployment in the delivery room to guide newborn resuscitation. The device uses forehead reflectance photoplethysmography (PPG) with modulated light and lock-in detection. Forehead fixation has numerous advantages including ease of sensor placement, whilst perfusion at the forehead is better maintained in comparison to the extremities. Green light (525 nm) was used, in preference to the more usual red or infrared wavelengths, to optimize the amplitude of the pulsatile signal. Experimental results are presented showing simultaneous PPG and electrocardiogram (ECG) HRs from babies (n = 77), gestational age 26-42 weeks, on a neonatal intensive care unit. In babies ⩾32 weeks gestation, the median reliability was 97.7% at ±10 bpm and the limits of agreement (LOA) between PPG and ECG were +8.39 bpm and -8.39 bpm. In babies <32 weeks gestation, the median reliability was 94.8% at ±10 bpm and the LOA were +11.53 bpm and -12.01 bpm. Clinical evaluation during newborn deliveries is now underway.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of a Low Cost Heart Monitor using Reflectance Photoplethysmogram

This paper presents a low cost design of heart beat monitoring device using reflectance mode PhotoPlethysmography (PPG). PPG is known for its simple construction, ease of use and cost effectiveness and can provide information about the changes in cardiac activity as well as aid in earlier non-invasive diagnostics. The proposed device is divided into three phases. First is the detection of pulse...

متن کامل

A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability

In this study, we investigated the difference between heart rate variability (HRV) derived from electrocardiogramic(ECG) signals and pulse rate variability (PRV) derived from photoplethysmographic(PPG) signals. Fourteen healthy subjects conducted the protocol: 10 min physiological signals including distal pulse wave on finger and ear from photoplethysmography (PPG), and heart beat from electroc...

متن کامل

A Noncontact Measurement of Cardiac Pulse Based on PhotoPlethysmoGraphy

Heart rate measurement is important for monitoring people’s phys‐ iological and body state. In this paper, a heart rate measurement methodology based on PhotoPlethysmoGraphy (PPG) signal is proposed. Human face positions are detected and tracked in real time by using facial color videos taken from cameras by non-contact shooting. Signals containing pulse components are extracted from images of ...

متن کامل

Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection

To study heart beat pulse wave propagation in real time and to evaluate the vascular blood flow resistance an important physiological parameter for vascular diagnostics. Photoplethysmography is a non-invasive technique that measures relative blood volume changes in the blood vessels close to the skin. PPG analysis emphasizes the importance of early evaluation of the diseases We present the resu...

متن کامل

BioWatch: Estimation of Heart and Breathing Rates from Wrist Motions

Continued developments of sensor technology including hardware miniaturization and increased sensitivity have enabled the development of less intrusive methods to monitor physiological parameters during daily life. In this work, we present methods to recover cardiac and respiratory parameters using accelerometer and gyroscope sensors on the wrist. We demonstrate accurate measurements in a contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 2014