An efficient method for the detection and elimination of systematic error in high-throughput screening
نویسندگان
چکیده
MOTIVATION High-throughput screening (HTS) is an early-stage process in drug discovery which allows thousands of chemical compounds to be tested in a single study. We report a method for correcting HTS data prior to the hit selection process (i.e. selection of active compounds). The proposed correction minimizes the impact of systematic errors which may affect the hit selection in HTS. The introduced method, called a well correction, proceeds by correcting the distribution of measurements within wells of a given HTS assay. We use simulated and experimental data to illustrate the advantages of the new method compared to other widely-used methods of data correction and hit selection in HTS. SUPPLEMENTARY INFORMATION Supplementary data are available at Bioinformatics online.
منابع مشابه
An efficient method for the detection and elimination of systematic error in igh - throughput screening h
Motivation: High-throughput screening (HTS) is an early-stage process in drug discovery which allows thousands of chemical compounds to be tested in a single study. We report a method for correcting HTS data prior to the hit selection process (i.e., selection of active compounds). The proposed correction minimizes the impact of systematic errors which may affect the hit selection in HTS. The in...
متن کاملComparative Approach to the Backward Elimination and for-ward Selection Methods in Modeling the Systematic Risk Based on the ARFIMA-FIGARCH Model
The present study aims to model systematic risk using financial and accounting variables. Accordingly, the data for 174 companies in Tehran Stock Exchange are extracted for the period of 2006 to 2016. First, the systematic risk index is estimated using the ARFIMA-FIGARCH model. Then, based on the research background, 35 affective financial and accounting variables are simultaneously used with t...
متن کاملNootropic Medicinal Plants; Evaluating Potent Formulation By Novelestic High throughput Pharmacological Screening (HTPS) Method
The principle of this method was to screen the pharmacological activity of six prepared polyphyto formulations by using high throughput screening method for their nootropic action. The study was performed in three stages using one, two and three animals, respectively in a group. Test formulations were given p.o daily at the dose of 50 and 100 mg/kg body weight. The test formulations were compar...
متن کاملApplication of Recursive Least Squares to Efficient Blunder Detection in Linear Models
In many geodetic applications a large number of observations are being measured to estimate the unknown parameters. The unbiasedness property of the estimated parameters is only ensured if there is no bias (e.g. systematic effect) or falsifying observations, which are also known as outliers. One of the most important steps towards obtaining a coherent analysis for the parameter estimation is th...
متن کاملSelective screening of 650 high risk Iranian patients for detection of inborn error of metabolism
Objective: Although metabolic diseases individually are rare ,but overall have an incidence of 1/2000 and can cause devastating and irreversible effect if not diagnosed early and treated promptly. selective screening is an acceptable method for detection of these multi presentation diseases.Method: using panel neonatal screening for detection of metabolic diseases in 650 high risk Iranian patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bioinformatics
دوره 23 13 شماره
صفحات -
تاریخ انتشار 2007