Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information
نویسندگان
چکیده
BACKGROUND To improve the accuracy of ultrasound-guided biopsy of the prostate, the non-rigid registration of magnetic resonance (MR) images onto transrectal ultrasound (TRUS) images has gained increasing attention. Mutual information (MI) is a widely used similarity criterion in MR-TRUS image registration. However, the use of MI has been challenged because of intensity distortion, noise and down-sampling. Hence, we need to improve the MI measure to get better registration effect. METHODS We present a novel two-dimensional non-rigid MR-TRUS registration algorithm that uses correlation ratio-based mutual information (CRMI) as the similarity criterion. CRMI includes a functional mapping of intensity values on the basis of a generalized version of intensity class correspondence. We also analytically acquire the derivative of CRMI with respect to deformation parameters. Furthermore, we propose an improved stochastic gradient descent (ISGD) optimization method based on the Metropolis acceptance criteria to improve the global optimization ability and decrease the registration time. RESULTS The performance of the proposed method is tested on synthetic images and 12 pairs of clinical prostate TRUS and MR images. By comparing label map registration frame (LMRF) and conditional mutual information (CMI), the proposed algorithm has a significant improvement in the average values of Hausdorff distance and target registration error. Although the average Dice Similarity coefficient is not significantly better than CMI, it still has a crucial increase over LMRF. The average computation time consumed by the proposed method is similar to LMRF, which is 16 times less than CMI. CONCLUSION With more accurate matching performance and lower sensitivity to noise and down-sampling, the proposed algorithm of minimizing CRMI by ISGD is more robust and has the potential for use in aligning TRUS and MR images for needle biopsy.
منابع مشابه
Non-rigid MRI-TRUS registration in targeted prostate biopsy
A non-rigid registration method is presented for the alignment of pre-procedural magnetic resonance (MR) images with delineated suspicious regions to intra-procedural 3D transrectal ultrasound (TRUS) images in TRUSguided prostate biopsy. In the first step, 3D MR and TRUS images are aligned rigidly using six pairs of manually identified approximate matching points on the boundary of the prostate...
متن کاملA Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملA shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy
This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires t...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملCompensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2017