68Ga PET/CT ventilation-perfusion imaging for pulmonary embolism: a pilot study with comparison to conventional scintigraphy.
نویسندگان
چکیده
UNLABELLED Ventilation-perfusion (V/Q) scintigraphy is established for regional assessment of lung function in a variety of diseases, including pulmonary embolism (PE). PET/CT may further improve the accuracy and utility of V/Q imaging because of its superior technical characteristics. This pilot study assessed the feasibility of performing V/Q PET/CT and compared diagnostic utility with conventional V/Q imaging in patients with clinical suspicion of PE. METHODS Ten patients undergoing conventional V/Q imaging were prospectively recruited. PET/CT V/Q imaging was performed after inhalation of (68)Ga-carbon nanoparticles ("Galligas") and administration of (68)Ga-macroaggregated albumin. Blinded to the results of the other study, SPECT/CT (n = 9) or SPECT (n = 1) images and PET/CT images were graded by a predefined scoring system for scan quality. The number of matched or unmatched defects and diagnosis were also measured and compared with a final diagnosis. RESULTS PET image quality was equivalent or superior to SPECT in all patients, with more homogeneous radiotracer distribution for both ventilation and perfusion studies (P < 0.01). Based on conventional V/Q imaging, the diagnosis was acute PE in 2 patients and no PE in 7 patients, and the imaging results were nondiagnostic in 1 patient. The PET/CT diagnosis was concordant in 8 patients, and these studies demonstrated a similar number and distribution of matched and unmatched defects. In 1 discordant case, a patient with a SPECT/CT study that was nondiagnostic because of severe airway disease showed no PE on PET/CT. In another, the diagnosis of PE established on SPECT/CT was not reported on PET/CT 2 d later, possibly because of interval clot lysis or migration. CONCLUSION This intraindividual comparative study demonstrated that V/Q PET/CT with (68)Ga-labeled radiotracers can be performed in clinical practice. Compared with conventional V/Q imaging, advantages include higher-resolution, fully tomographic images with potentially better regional quantitation of lung function. The short half-life of (68)Ga also enables more flexible acquisition protocols with the option of performing ventilation studies selectively on patients with abnormal perfusion. On the basis of our results, further studies are indicated to assess whether V/Q PET/CT can improve diagnostic algorithms for patients with suspected PE.
منابع مشابه
Combined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship
Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...
متن کاملTomographic imaging in the diagnosis of pulmonary embolism: a comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT.
UNLABELLED Although ventilation/perfusion (V/Q) lung scintigraphy is a well-accepted and frequently performed procedure in the diagnosis of pulmonary embolism, there is growing controversy about its relevance, particularly due to the increasing competition between scintigraphy and CT. Even though comparative studies between both modalities have already been performed, their results were highly ...
متن کاملDiagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors
Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...
متن کاملSpurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging
Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...
متن کاملRole of computed tomography and magnetic resonance imaging for deep venous thrombosis and pulmonary embolism.
During the 1990s, computed tomography (CT) and magnetic resonance (MR) imaging underwent extensive technological advancement and expanded clinical use in patients with venous thromboembolic disease, particularly with regard to evaluation of the pulmonary vasculature. In many institutions, helical (spiral) CT pulmonary angiography has become the initial imaging study of choice to evaluate patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 52 10 شماره
صفحات -
تاریخ انتشار 2011