Using Willie's acid-base box for blood gas analysis.

نویسنده

  • John R Dietz
چکیده

Many years ago, I was asked to evaluate a method developed by Dr. William T. Lipscomb for teaching blood gas analysis of acid-base status. Dr. Lipscomb was a Professor in the Department of Physiology of the University of Nebraska College of Medicine during my graduate student days and served as a teaching mentor to myself and several other graduate students for our first physiology lectures. Dr. Lipscomb went on to teach anatomy and physiology at Costal Georgia Community College for 18 yr and after retiring and served as Secretary for the Glynn Environmental Coalition until his death in 2005. Glynn Environmental Coalition named a science award in his honor as he was a much-loved teacher. When I first examined this approach, it seemed much too simplistic for medical students, but I decided to try it in my lectures. First, I present the standard Henderson-Hasselbalch equation and apply this to some simple patient problems but then reexamine the patient cases using Willie’s acid-base box. Invariably, some of the students find it silly at first, but every single year I have some more senior students who come back to this method. For example, a recent second-year medical class tackling acid-base cases in a course titled “EvidenceBased Medicine” contacted me to review “Willie’s box.” Even third-year medical students have found the method useful to prepare for an Internal Medicine Shelf exam. Also, students have e-mailed me after exams attesting that this method was helpful in securing correct answers on various board-style tests. Before dismissing this method, give it a try, as I’m sure many of your students will enjoy it and benefit in the long run. The box is constructed using three of the parameters of standard arterial blood gas analysis: pH, bicarbonate, and CO2. Therefore, it depicts the Henderson-Hasselbalch equation in a simple visual form that requires no calculations. The top value depicts the pH with the normal range of 7.35–7.45 and is considered inside the box. Anything below that range is outside the box and identifies acidosis, whereas any value above the range is outside the box to the right and depicts alkalosis. The middle line represents the metabolic component of the acidbase system, which is measured clinically as bicarbonate. I took the liberty of broadening the normal range for this value from Dr. Lipscomb’s original to account for the immediate changes in bicarbonate that result from CO2 conversion to bicarbonate by buffering from hemoglobin (1). The first case (Fig. 1) shows a patient who is experiencing an acute asthma attack with the following blood gas values: pH 7.27, bicarbonate 26 meq/l, and CO2 60 mmHg. Willie’s

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manganese (III)-Bis(salicylaldehyde)-4-Methyl-1,2-Phenylenediimine (Mn-BSMP) as an Inexpensive N2O2 Type Schiff Base Catalyst for Oxidative Decarboxylation of Carboxylic Acids with (n-Bu4NIO4) in the Presence of Imidazol

In this study, bis(salicylaldehyde)-4-methyl-1,2-phenylenediimine (BSMP) as a Schiff base ligand of N2O2-type and its Mn and Fe complex as M-BSMP catalyst were synthesized and characterized by UV-Vis, IR spectroscopy and elemental analysis. The efficiency of Fe- and Mn-BSMP catalysts was evaluated in the oxidative decarboxylation of arylacetic acids with tetra...

متن کامل

Acid and Base Catalyzed Transesterification of Animal Fats to Biodiesel

The present study has been focused on the acid and base transesterification of animal fats (dairy cow and beef) to produce biodiesel by varying process parameters such as catalyst amount, catalyst nature, reaction time and temperature. The maximum biodiesel yield after acid catalysis was 94.1 ± 2.43 and 98.4 ± 2.3 percent for dairy cow and beef t...

متن کامل

Determination of Neonatal Prognosis Based on Umbilical Vein Blood Gas in Hakim Hospital of Neyshabur, Iran during 2017-2018

Background: In order to determine the prognosis of neonates, it is recommended to use umbilical gas analysis in all high-risk pregnancies. However, utilizing umbilical gas analysis and Apgar score together is very helpful for determining the mortality rate confidence interval. Therefore, in this study, we investigated the application of umbilical gas analysis in assessing the prognosis of infan...

متن کامل

Voltammetric Detection of Dopamine and Ascorbic Acid Using a Multi-Walled Carbon Nanotubes/Schiff Base Complex of Cobalt-Modified Glassy Carbon Electrode

The surface of the glassy carbon electrode (GCE) is modified with the composite of new Cobalt complex with a tetradentate Schiff base ligand derived from 3-ethoxysalicylaldehyde and 4,5-dimethyl orthophenylenediamine (CoOEtSal) and multi-walled carbon nanotube (MWCNT). The electrochemical oxidation of ascorbic acid (AA) and dopamine (DA) at the modified electrode was studied using the cyclic an...

متن کامل

Bubble formation on a single orifice in a gas solid fluidized bed using digital image analysis

Digital Image Analysis (DIA) has been employed to characterize the time evolution of a bubble injected from a single orifice into a pseudo 2-dimansional gas-solid fluidized bed. The injected bubble diameter increased with the square root of time before detachment. During bubble free flight in the bed, its diameter remains approximately constant. The center of mass of the bubble increases with t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Advances in physiology education

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2011