Salivary cortisol on ROCHE Elecsys immunoassay system: pilot biological variation studies.
نویسندگان
چکیده
OBJECTIVES Salivary analysis is a noninvasive alternative that may be more acceptable to patients, especially children. As such, it has the potential for incorporation into comprehensive, dynamic investigations of metabolic dysfunctions - a significant advancement over a single time point serum analysis. In this study, we wanted to determine if the serum cortisol assay on our routine immunoassay analyzer could reliably measure salivary cortisol concentrations. Because of potential fluctuations in salivary concentrations, we included a biologic variation study as a main facet of our preliminary method evaluation. DESIGN AND METHODS Twenty-eight healthy individuals (12 males, 16 females) volunteered to provide 5 nonconsecutive first morning saliva samples over a two-week period. Samples were stored frozen at home until the completion of the study. Following thawing and centrifugation, cortisol was measured in batch mode for each set of participant samples on the ROCHE Elecsys. Biologic variation was determined following removal of outliers. A method comparison was performed with the DPC Coat-A-Count Cortisol assay following the recommended modifications for salivary analysis, and with the Salimetrics HS-Cortisol two-site monoclonal assay optimized for salivary cortisol. RESULTS Mean salivary cortisol concentration was 20.4 nmol/L. Analytical variation (CV(A) = 3.8%), within-subject variation (CV(I) = 6.3%), between-subject variation (CV(G) = 20.5%), index of individuality (II = 0.36) and reference change value (RCV = 20.4%) were determined. A negative 40% proportional bias was observed on the Elecsys compared to the two methods that have already been optimized for salivary analysis. CONCLUSIONS This study demonstrated that salivary cortisol can be reliably measured on a routine automated immunoassay analyzer such as the ROCHE Elecsys. This particular assay needs to be optimized at the low end of the standard curve for routine use with salivary samples. Based on the relatively small intra-individual variation and low index of individuality, reference change values are preferable to the use of population reference intervals for this assay.
منابع مشابه
Measurement of late-night salivary cortisol with an automated immunoassay system.
BACKGROUND Measurement of late-night salivary cortisol concentrations is increasingly used as a screening test in suspected Cushing's syndrome. Cortisol concentrations are typically extremely low in late-night samples and discordant assay-specific reference ranges have been reported. Therefore, the aim of our study was to assess the analytical performance of the first automated cortisol immunoa...
متن کاملAutomated measurement of 25-OH vitamin D3 on the Roche Modular E170 analyzer.
BACKGROUND The first commercial direct automated immunoassay specific for 25-OH vitamin D(3) (25-OH-D(3)) was recently introduced for use on Roche Diagnostics immunoassay analyzers. We assessed the analytical performance of the Elecsys 25-OH-D(3) assay on a Roche Modular E 170 analyzer. METHODS The Elecsys 25-OH-D(3) assay is a direct electrochemiluminescence immunoassay for human serum or pl...
متن کاملDiurnal Salivary Cortisol following Mindfulness-Based Cognitive Therapy (MBCT) in Women with Breast Cancer: A pilot Study
ABSTRACT Background and Objectives: Cancer and its conventional treatments may bring about some psychological and health-related symptoms leading to unstable cortisol level. Since evidence has shown that mindfulness based approaches can be helpful to reduce cortisol level, we aimed at investigating the efficacy of &n...
متن کاملCross-reactivity of steroid hormone immunoassays: clinical significance and two-dimensional molecular similarity prediction
BACKGROUND Immunoassays are widely used in clinical laboratories for measurement of plasma/serum concentrations of steroid hormones such as cortisol and testosterone. Immunoassays can be performed on a variety of standard clinical chemistry analyzers, thus allowing even small clinical laboratories to do analysis on-site. One limitation of steroid hormone immunoassays is interference caused by c...
متن کاملAssessment of salivary free cortisol levels by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in patients treated with mitotane.
OBJECTIVE Mitotane is an adrenocytolytic agent used in adrenocortical carcinoma, inducing adrenal insufficiency, requiring replacement treatment. Such therapy is not easy to monitor because of mitotane interference. Salivary cortisol reflects a free fraction of plasma cortisol and may be useful in such patients. DESIGN The aim of our study was to evaluate salivary cortisol by HPLC coupled to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical biochemistry
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2003