Objective assessment of limb tissue elasticity: development of a manual indentation procedure.

نویسندگان

  • Y Zheng
  • A F Mak
  • B Lue
چکیده

An ultrasound indentation system with a pen-size hand-held probe was developed and used to obtain the effective Young's moduli of forearm and lower limb soft tissues in 12 subjects. Since the probe is manually driven, the alignment of the probe and control of the rate of indentation are parameters upon which the results obtained depend. This paper addresses whether manual indentation tests with the probe are sufficiently acceptable and repeatable for objective biomechanical characterization of limb tissues. Forearms of three normal subjects were tested in two states of muscular contraction. Six different indentation rates, ranging from 0.75 mm/s to 7.5 mm/s, were imposed. The load-indentation responses obtained were shown to be well represented by quadratic functions. A linear elastic indentation solution was used to extract the effective Young's modulus. The material parameters extracted were repeatable and rather rate-insensitive for the range of rates used. The effective Young's modulus obtained was found to significantly increase as a result of contraction of the underlying muscles. Indentor misalignment experiments demonstrated that misalignment affects the measurement from which the effective Young's modulus of soft tissues is calculated. This effect, however, was found to decrease as the tissue thickness increased. With the investigation of the above issues, a procedure has been established for the extraction of effective Young's moduli of limb soft tissues from manual cyclic indentation responses. Tests on experimental subjects' lower limbs further demonstrated that the ultrasonic indentor is a feasible instrument for characterization of the biomechanical properties of limb soft tissues. Paired-t tests showed that the effective Young's moduli of the lower limb soft tissues of three elderly persons with transtibial amputation were significantly smaller than those of six unimpaired young subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of lower-limb tissue perfusion during loading.

An extant tissue indentor used for amputee residual limb tissue indentation studies was modified to include laser Doppler flowmetry (LDF) to enable measurement of tissue perfusion during indentation. This device allows quantitative assessment of the mechanical and physiological response of soft tissues to load, as demonstrated by indentation studies of the lower-limb tissues of young healthy su...

متن کامل

Effective elastic properties for lower limb soft tissues from manual indentation experiment.

Quantitative assessment of the biomechanical properties of limb soft tissues has become more important during the last decade because of the introduction of computer-aided design and computer-aided manufacturing (CAD/CAM) and finite element analysis to the prosthetic socket design. Because of the lack of a clinically easy-to-use apparatus, the site and posture dependences of the material proper...

متن کامل

Radiological and Histological Assessment of the Ossification Centers of Hind Limb after Hatching in Pigeon

Objective- The aim of this study was to determine the age of physical maturity and evaluation of radiology and histology of hind limb ossification centers in pigeon. Design- Fundamental study. Animals- 14 pigeons. Procedures- These pigeons were cultivated in identical and standard conditions and radiological and histological tests performed every 7 days to 91 days. Resu...

متن کامل

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

Biomechanical assessment of below-knee residual limb tissue.

In vivo indentation properties of the residual limb tissues of a group of senior subjects with below-knee (BK) amputation were measured and compared with those of nondisabled young adults. It was found that differences attributable to site variations, states of muscular activity, and the differences between the nondisabled young group and the group consisting of the seniors with amputation were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 1999