Shaping potential of manual NiTi K-File and rotary ProTaper and analyzing the final outcome of shaped canals using CT.

نویسندگان

  • Surbhi Kakar
  • Anil Dhingra
  • Himanshu Sharma
چکیده

AIM To assess and compare the shaping potential of manual NiTi K-files and Rotary ProTaper instruments in narrow canals using CT. OBJECTIVE To assess the shaping potential of manual NiTi K-files and Rotary ProTaper and analyzing the final outcome of shaped canals using CT and determining different variables, like • Working time • Change in volume • Change in cross-sectional area. MATERIALS AND METHODS From a pool of fifty freshly extracted permanent maxillary molars (1st and 2nd), 30 were selected with curvatures (20 to 40°) (Schneider 1971). Tissue fragments and calcified debries were removed from the teeth by scaling. The teeth were then stored in normal saline until used. All the mesiobuccal canals were scanned by CT to obtain preinstrumented images. Teeth were scaled and stored in normal saline. This study was divided in two groups with 15 samples each. GROUP I (PROTAPER ROTARY): Canals were instrumented with Protaper Rotary instruments using crown down technique according to manufacturer's instructions. GROUP II (NITI K-FILE): Were instrumented by NiTi K-files using step back technique with a quarter turn/pull motion. EVALUATIONS OF WORKING TIME: Comparative evaluations of working time was done for both the experimental groups. CT ANALYSIS AND MEASUREMENTS: The samples were analyzed and evaluated for: • Postinstrumentation change in volume. • Postinstrumentation change in cross-sections area. RESULT From the observations and statistical analysis carried out in this study, it was found that: There was a statistically significant difference between all the parameters judged for the present study that is: 1. Instrumentation with ProTaper Rotary system took significantly less time than instrumentation with manual NiTi K-file. 2. Change in the canal volume following instrumentation with ProTaper Rotary was significantly greater than that produced by manual NITi K-file. 3. a. Change in cross-section area at 2 and 3 mm from the apex was significantly greater with manual NiTi K-file as compared to ProTaper Rotary. b. Change in cross sections at 4.5, 6 and 7.5 mm from the apex with ProTaper Rotary was significantly greater than that produced by manual NITi K-file. CONCLUSION This clearly establishes that there is a drastic difference in the shaping ability of manual and Rotary NiTi instruments used with step back and crown down technique respectively with the rotary instrumentation being faster and producing greater changes in the canal anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه آزمایشگاهی کارایی روشهای چرخشی Profile، Protaper،  Flex Master و دستی NiTi K-File در آماده‌سازی کانال ریشه

Statement of Problem: Root canal cleaning and shaping are important steps in endodontic therapy. In order to develop better techniques, new instruments are constantly designed and delivered to the market.Purpose: The aim of the present study was to compare the effectiveness of one manual with three rotary root canal instrumentations techniques.Materials and Methods: In this in-vitro study, 80 m...

متن کامل

Ex Vivo Comparison of File Fracture and File Deformation in Canals with Moderate Curvature: Neolix Rotary System versus Manual K-files

Background and Aim: Cleaning and shaping is one of the important steps in endodontic treatment, which has an important role in root canal treatment outcome. This study evaluated the rate of file fracture and file deformation in Neolix rotary system and K-files in shaping of the mesiobuccal canal of maxillary first molars with moderate curvature.    Materials and Methods: In this ex vivo exp...

متن کامل

Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

AIMS The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. SUBJECTS AND METHODS Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instruct...

متن کامل

Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth

Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...

متن کامل

مقایسه آماده‌سازی کانال ریشه با استفاده از فایل‌های نیکل تیتانیومی دستی و روتاری Race

Introduction: Successful treatment of root depends on complete elimination of debris and bacteria’s from root canal system and appropriate shaping of canal in obturation canal preparation is the most difficult and time consuming stage during root canal treatment. This stage especially in curved and narrow canals always causes some problems for students, general dentist and specialist. Following...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2013