The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
نویسندگان
چکیده
Electroretinography (ERG) is a reliable diagnostic tool for the diagnosis of retinal disease. It measures electric potentials occurring in the retina in response to light stimulation. In this study, we examined the normal electroretinogram using the Handheld Multispecies ERG (HMsERG) in Shih Tzu dogs. ERG recordings were performed in twelve eyes of six healthy Shih Tzu dogs. Dogs were anesthetized with a combination of medetomidine and ketamine. Proparacaine eye drops were also applied as a topical anesthetic. Tropicamide eye drops were applied for mydriasis. After 20 min of dark adaptation, we recorded the amplitudes and implicit times of the b-waves of the rod, standard rod and cone (Std R&C), high-intensity rod and cone (Hi-int R&C), and cone systems, and responses of the cones and inner retina by flicker light stimulation (cone flicker). Results showed that mean the amplitudes of a-waves of Std R&C, Hi-int R&C, and the cone responses were 141.25 microV 173.00 microV and 12.92 microV respectively. The b-waves of the rod responses ranged from 141.58 to 155.25 microV the Std R&C was 314.75 microV the Hi-int R&C was 329.42 microV the cones were 37.75 microV and the flicker responses were 64.08 microV The b/a ratios for the Std R&C, Hi-int R&C, and the cone response were 2.29, 1.94, and 3.71, respectively. Mean implicit time of the a-wave of the Std R&C was 15.12 ms, of Hi-int R&C was 13.42 ms, and of the cone response was 7.22 ms. The b-wave of the rod responses ranged from 68.12 to 72.68 ms, of Std R&C were 37.28 ms, of Hi-int R&C were 41.90, of the cone responses were 38.12 ms, and of the cone flicker responses were 22.80 ms. We believe that these parameters can be used as reference "normal" ERGs ranges for Shih Tzu dogs using the HMsERG under medetomidine and ketamine anesthesia.
منابع مشابه
Comparison of two electroretinography systems used in dogs: the HMsERG and the RETIport.
The purpose of the study was to compare two different electroretinography (ERG) instruments used on the same animal in a laboratory setting. Retinal function in both eyes of 12 healthy miniature schnauzers was evaluated under general anesthesia. Scotopic and photopic ERGs were recorded by the HMsERG and the RETIport using the Dog Standard Protocol recommended by the European College of Veterina...
متن کاملPericardial effusion in a dog concurrent with carcinoma of unknown primary origin
Background: Pericardial effusion (PE) due to secondary metastasis has rarely been reported in dogs. Case description: This case describes clinical signs and further diagnostics regarding metastatic carcinoma of unknown primary origin (CUP) in refractory PE of a dog. Findings/treatment and outcome: A nine-year-old, castrated mal...
متن کاملNormal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs
Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...
متن کاملChemical Sterilization by Intratesticular Injection of Eugenia Caryophyllata Essential Oil in Dog: A Histopathological Study
Objective- To study a method of chemical sterilization and its efficacy in adult male dogs. Design- Experimental study. Animals- Ten healthy adult mixed breed dogs Procedures- Eugenia caryophyllata (EC) essential oil was injected into the dorsal cranial portion of each testicle of five dogs (treatment group). The same volume of normal saline was injected in the same site of testicles in the ...
متن کاملThe electroretinogram in dogs with inherited cone degeneration.
The electroretinogram (ERG) of hemeralopic Alaskan malamute dogs contains only rod components. There is absence of the photopic b-wave which is normally elicited with red light stimuli during dark adaptation and, using flicker stimulation, only the first or rod branch of the flicker fusion response curve is present. At high stimulus intensity levels, the flicker response of hemeralopes is absen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2009