Minimizing dead-periods in flow-encoded or -compensated pulse sequences while imaging in oblique planes.

نویسندگان

  • B D Bolster
  • E Atalar
چکیده

A technique is developed to minimize magnetic resonance pulse sequence dead-periods, with first and higher moment requirements, while imaging in oblique planes. Dead-period requirements of starting amplitude, ending amplitudes, area, and other moment requirements are transformed from the image coordinate system to the physical gradient coordinate system, where the waveforms are then designed. With this technique, the full capabilities of the gradient hardware are utilized. An online algorithm is presented to perform dead-period minimization and gradient waveform design when the first moment and area of the dead-period are specified. The algorithm is then used to implement three-axis flow-compensation in a fast spoiled gradient-echo sequence. This results in a minimal increase in TE and TR over an equivalent non-flow-compensated sequence, and little variation in the minimum TR over the entire range of oblique slice orientations. Applications of this algorithm extend to the optimization of any pulse sequence in which the first moment is important and oblique imaging is required. J. Magn. Reson. Imaging 1999;10:183-192.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-42: MRI Evaluation of Congenital Uterine Anomalies

Mullerian duct anomalies are an uncommon but often treatable cause of infertility. Patients with müllerian duct anomalies are known to have a higher incidence of infertility, repeated first-trimester spontaneous abortions, fetal intrauterine growth retardation, fetal malposition, preterm labor, and retained placenta. The role of imaging is to help detect, diagnose, and distinguish surgically co...

متن کامل

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

PC VIPR for Comprehensive Cardiovascular Evaluation in Congenital Heart Disease

Introduction Imaging of congenital heart disease usually requires multiple anatomical and functional scans followed by several 2D phase contrast (PC) acquisitions in a variety of oblique scan planes for flow measurements. A new PC acquisition technique has been developed using vastly undersampled isotropic projection reconstruction (PC VIPR) [1], which allows for volumetric 3D CINE flow imaging...

متن کامل

Rapid phase contrast MRI with minimum time gradient waveform design using convex optimization

Background Phase contrast MRI (PC-MRI) sequences conventionally use triangular and trapezoidal gradient waveforms to construct flow compensated and flow encoded (FCFE) [1] or Bipolar [2] velocity encoding gradients. This approach does not make optimal use of the available gradient hardware for all time points, but convex optimization (CVX) can be used to design minimum-duration, arbitrarily sha...

متن کامل

Comparison of gradient-recalled-echo and T2-weighted spin-echo pulse sequences in intramedullary spinal lesions.

Nineteen consecutive patients with spinal intramedullary lesions were studied on a 1.5-T system to compare the quality of T2-weighted spin-echo and gradient-recalled-echo (GRE) pulse sequences. Direct comparisons were made in the sagittal and/or axial planes. Twenty-four studies were performed in the 19 patients. The gradient echoes were usually performed at 300/14 (TR/TE) with a flip angle of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 1999