Quantification of Nonenhancing Tumor Burden in Gliomas Using Effective T2 Maps Derived from Dual-Echo Turbo Spin-Echo MRI.

نویسندگان

  • Benjamin M Ellingson
  • Albert Lai
  • Huytram N Nguyen
  • Phioanh L Nghiemphu
  • Whitney B Pope
  • Timothy F Cloughesy
چکیده

PURPOSE Evaluation of nonenhancing tumor (NET) burden is an important yet challenging part of brain tumor response assessment. This study focuses on using dual-echo turbo spin-echo MRI as a means of quickly estimating tissue T2, which can be used to objectively define NET burden. EXPERIMENTAL DESIGN A series of experiments were performed to establish the use of T2 maps for defining NET burden. First, variation in T2 was determined using the American College of Radiology (ACR) water phantoms in 16 scanners evaluated over 3 years. Next, the sensitivity and specificity of T2 maps for delineating NET from other tissues were examined. Then, T2-defined NET was used to predict survival in separate subsets of patients with glioblastoma treated with radiotherapy, concurrent radiation, and chemotherapy, or bevacizumab at recurrence. RESULTS Variability in T2 in the ACR phantom was 3% to 5%. In training data, ROC analysis suggested that 125 ms < T2 < 250 ms could delineate NET with a sensitivity of >90% and specificity of >65%. Using this criterion, NET burden after completion of radiotherapy alone, or concurrent radiotherapy, and chemotherapy was shown to be predictive of survival (Cox, P < 0.05), and the change in NET volume before and after bevacizumab therapy in recurrent glioblastoma was also a predictive of survival (P < 0.05). CONCLUSIONS T2 maps using dual-echo data are feasible, stable, and can be used to objectively define NET burden for use in brain tumor characterization, prognosis, and response assessment. The use of effective T2 maps for defining NET burden should be validated in a randomized, clinical trial.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

High resolution T2 weighted Lung Imaging with a radial Turbo Spin-Echo Sequence

Introduction: MRI of the lung is still a challenging task due to its inherently low proton density, continuous movement caused by respiration and heartbeat, as well as a very short T2* relaxation time of roughly 1-2 ms at 1.5 T [1]. The latter of which can be overcome by using Spin-Echo type sequences which correct for additional spin dephasing owing to inhomogeneities at the numerous air-tissu...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

MRI assessment of brain iron content in methamphetamine users

Introduction: Methamphetamine (MA) abuse produces long term changes to the dopamine system that likely contribute to the psychiatric and cognitive symptoms that are seen in MA users. Emerging evidence from preclinical studies suggests that brain iron accumulation plays a role in MA toxicity, both as a biomarker of damage and a potential source of oxidative stress; however, this relationship has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical cancer research : an official journal of the American Association for Cancer Research

دوره 21 19  شماره 

صفحات  -

تاریخ انتشار 2015