Methods for fatigue testing off-road bicycle handlebars based on assembly effects using two different stem designs
نویسندگان
چکیده
Assembly of off-road bicycle handlebars with a stem that clamps the handlebar around its circumference would be expected to affect fatigue performance by introducing both assembly stresses and stress concentration. Because the effect of clamping on fatigue performance is unknown and because of the need to insure structural reliability in the stem-handlebar assembly to prevent serious injury, the objectives of the work reported by the present article were fourfold. One was to determine the stresses due to assembly and the stress concentration induced in a handlebar for two different clamp designs (i.e. 1-bolt and 2-bolt), a second was to determine experimentally the high cycle constant amplitude load fatigue lives of the two stem-handlebar assemblies, a third was to determine experimentally the variable amplitude load fatigue lives, and the fourth was to predict the variable amplitude load fatigue life with constant amplitude load fatigue test results. The handlebar was instrumented with strain gages and the assembly strains were measured when the stem clamps were tightened. The handlebar was also loaded as a cantilever beam while the applied strains were measured for each assembly. Stresses were computed and the maximum stresses induced by clamping exceeded 200 MPa for both assemblies. A method unique to this study was devised to determine the stress concentration at an arbitrary angular location around the circumference of the handlebar and for an arbitrary loading direction in the plane of the bicycle. For a load directed along an angle of -38degrees (clockwise rotation from horizontal viewed from the right), both stems created similar stress concentration; the location of maximum applied stress was shifted by 30degrees from the point that would be expected in the absence of assembly and the stress was increased by 40% at this location. The measured fatigue lifetimes for constant amplitude loading were similar for the two stem designs but the variable amplitude load fatigue lifetime for the 1-bolt stem assembly was shorter than that for the 2-bolt
منابع مشابه
Quantification of structural loading during off-road cycling.
To provide data for fatigue life prediction and testing of structural components in off-road bicycles, the objective of the research described herein was to quantify the loads input to an off-road bicycle as a result of surface-induced loads. A fully instrumented test bicycle was equipped with dynamometers at the pedals, handlebars, and hubs to measure all in-plane structural loads acting throu...
متن کاملA single loading direction for fatigue life prediction and testing of handlebars for off-road bicycles
Components for off-road bicycles including handlebars continue to be recalled with regularity because of problems with structural failure as a result of high cycle fatigue in the off-road environment. The objectives of this study were to 1) devise a method for determining the point on the handlebar cross section that experiences the maximum cumulative damage when the handlebar is subjected to l...
متن کاملThe relationship of bicycle manoeuvrability to handlebar configuration.
Since the handling characteristics of bicycles can affect their safety, the present experiment evaluated the manoevrability of three bicycles which differed only by handlebar configurations: racing (Maes Bend), standard, and high rise. The manoeuvrability of each bicycle was measured as subjects performed six tasks: circle, lane change, figure-eight, straight lane tracking, cornering, and slalo...
متن کاملComparison the effects of two pedaling methods on lower limb muscles activity and fatigue index in road cyclists
The aim of this study was to compare the effects of two pedaling methods on lower limb muscles fatigue index and muscular activity in road cyclists. For this purpose eight road cyclists participated in two separately session in laboratory. They were pedaling with pushing technique in first session and circling (pullingpushing) technique in the other session. Surface electromyography activity...
متن کاملEMG-based Fatigue Assessment During Endurance Testing With Different VT Protocols
BACKGROUND: Muscle fatigue can be defined as the failure of a muscle to maintain a reasonably expected force output. The multivariate approach to fatigue assessment is used because the multiple (EMG) feature provides more information than anyone. OBJECTIVE: This study presents a method of assessing muscle fatigue during endurance testing at 50% maximal voluntary contraction (MVC) using electro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002