Gastroesophageal perforation after intraoperative transesophageal echocardiography.
نویسندگان
چکیده
THE use of transesophageal echocardiography for intraoperative monitoring of cardiac function is increasing. Complications are rare. Oropharyngeal injury and hypopharyngeal perforation during difficult insertion of the echoprobe in anesthetized patients have been reported. [1,2] One case of perforation of the cervical esophagus in an awake patient after multiple attempts at insertion of the echoprobe has been reported. [3] Esophageal perforation from an echoprobe in an anesthetized patient, however, has not been published. We observed and report a case of perforation of the gastroesophageal junction in an anesthetized patient after an easy insertion of the echoprobe that yielded good quality transesophageal echocardiograms.
منابع مشابه
The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patients.
UNLABELLED Transesophageal echocardiography (TEE) is an invaluable intraoperative diagnostic monitor that is considered to be relatively safe and noninvasive. Insertion and manipulation of the TEE probe, however, may cause oropharyngeal, esophageal, or gastric trauma. We report the incidence of intraoperative TEE-associated complications in a single-center series of 7200 adult cardiac surgical ...
متن کاملAortic valve leaflet perforation after mitral valve repair.
A 32-year-old patient with symptomatic severe aortic regurge, 6 weeks after mitral valve repair, was admitted for aortic valve surgery. No preoperative clinical data consistent with infective endocarditis could be detected. Preoperative transthoracic echocardiography showed aortic leaflet perforation affecting non coronary cusp. During operation, leaflet perforation was detected and closed comp...
متن کاملDelayed presentation of gastric perforation after transesophageal echocardiography for cardiac surgery.
TRANSESOPHAGEAL echocardiography (TEE) is an integral tool for intraoperative monitoring and diagnosis in patients undergoing cardiac surgery. TEE remains a moderately invasive procedure with a very low incidence of complications, ranging from 0.2% to 1.2%. The spectrum of complications has included injury to the gastrointestinal tract, obstruction of airways, dysrhythmias, hemorrhage, or entra...
متن کاملAnterior mitral leaflet perforation identified by real time three-dimensional transesophageal echocardiography.
With its unique en face view, real time three-dimensional transesophageal echocardiography has been reported to be more precise than conventional two-dimensional studies in evaluating mitral regurgitation etiology, and can locate diseased segments correctly. We present a case with severe mitral regurgitation due to anterior mitral leaflet perforation. Intraoperative real time three-dimensional ...
متن کاملMallory - weiss tear complicating intraoperative transesophageal echocardiography.
A Mallory - Weiss tear occurred as a complication of intraoperative transesophageal echocardiography carried out in a 62-year-old man who underwent coronary artery bypass grafting. Left ventricular function was monitored in the transgastric short-axis view. Postoperative esophagogastroscopy revealed a Mallory - Weiss tear at the gastroesophageal junction and erosions in the cardia, presumably s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 85 2 شماره
صفحات -
تاریخ انتشار 1996