Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.

نویسندگان

  • Barbara C Gilligan
  • Mark Shults
  • Rathbun K Rhodes
  • Peter G Jacobs
  • James H Brauker
  • Thomas J Pintar
  • Stuart J Updike
چکیده

The feasibility of continuous long-term glucose monitoring in humans has not yet been demonstrated. Enzyme-based electrochemical glucose sensors with telemetric output were subcutaneously implanted and evaluated in five human subjects with type I diabetes. Subject-worn radio-receiver data-loggers stored sensor outputs. Every 1-4 weeks the subject's glucose levels were manipulated through the full clinical range of interest using standard protocols. Reference blood glucose samples were obtained every 5-10 min and analyzed in our hospital clinical laboratory and/or on glucose meters. The sensor data were evaluated versus the reference data by linear least squares regression and by the Clarke Error Grid method. After surgical explantation and device inspection, the tissue-sensor interface was evaluated histologically. The remaining sensor-membranes were also recalibrated for comparison with preimplant performance. Four of the five glucose sensors tracked glucose in vivo. One sensor responded to manipulated glucose changes for 6.2 months with clinically useful performance (>/=90% of sensor glucose values within the A and B regions of the Clarke Error Grid). For this sensor, recalibration was required every 1-4 weeks. The other three transiently responding sensors had electronic problems associated with packaging failure. The remaining sensor never tracked glucose because of failure to form any sustained connection to adjacent subcutaneous tissue. Thus, stable, clinically useful sensor performance was demonstrated in one of five subjects with diabetes for a sustained interval of greater than 6 months. While this glucose sensor implant technology shows promise in humans, it needs to be made more reliable and robust with respect to device packaging and sensor-tissue connection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Editorial: symposium on algorithms for continuous glucose monitoring and control.

1 S YSTEMS AND CONTROL THEORY is the basis for algorithms embedded in many of the products (both high and low " tech ") that we use in our daily lives. While consumers appreciate the relative compactness of CD and DVD players and microdrives, for example, and value the manufacturing technology involved in minia-turization, they probably do not think much about the mathematical algorithms that e...

متن کامل

Minimally invasive enzyme microprobes: an alternative approach for continuous glucose monitoring.

Corresponding Author: Anthony Cass, D.Phil., FRSC, Institute of Biomedical Engineering, Department of Chemistry, Imperial College London, South Kensington Campus, Exhibition Road, London SW7 2AZ; email address [email protected] Continuous glucose monitoring has been shown to improve glycemia in diabetes.1,2 To minimize the pain, inconvenience, and discomfort associated with long-term implan...

متن کامل

Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Tight glycemic control slows or prevents the development of short- and long-term complications of diabetes mellitus. Continuous glucose measurements provide improved glycemic control and potentially prevent these diabetic complications. Glucose sensors, especially implantable devices, offer an alternative to classical self-monitored blood glucose levels and have shown promising glucose-sensing ...

متن کامل

A Microfabricated Dielectric Affinity Sensor for Continuous Glucose Monitoring

We present a microfabricated affinity sensor using permittivity measurement for continuous glucose monitoring (CGM). This device is based on a perforated electrode separated from a bottom electrode on a substrate by a solution of a synthetic glucose-sensitive polymer. Glucose permeates through the perforated electrode and binds with the polymer, leading to a change in the polymer solution permi...

متن کامل

Evaluation of sensor sites for continuous glucose monitoring in cats with diabetes mellitus.

The continuous glucose monitoring system allows generation of detailed glucose curves via measurement of glucose concentration in interstitial fluid. The conventional site for sensor placement in diabetic cats is the subcutaneous tissue of the lateral chest wall. The aim of this study was to investigate the feasibility and accuracy of sensors placed in the lateral chest wall and in two alternat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 2004