aradoxical undersensing due to quiet timer blanking

نویسنده

  • Robert F. Rea
چکیده

r l h b w Inappropriate sensing of atrial and ventricular electrical ctivity is a common cause of pacemaker malfunction and is outinely screened for during pacemaker clinic visits. Unersensing is typically resolved by programming the voltage evel required for sensing to lower, ie, more sensitive, levls. This report discusses a situation in which, paradoxially, undersensing was resolved by programming the voltge level required for sensing to higher, ie, less sensitive, evels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paradoxical undersensing during atrial flutter: what is the mechanism?

A patient with congenital complete heart block underwent implantation of a dual-chamber pacemaker. He presented to the emergency room with fatigue and was found to be in atrial flutter. Device interrogation revealed undersensing of 5 mV flutter waves at a programmed sensitivity of 0.5 mV. Due to undersensing, mode switch did not occur. This case illustrates apparently paradoxical undersensing o...

متن کامل

Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators

Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators Accurate atrial sensing during tachycardia is essential for reliable determination of atrial rate, which is a critical component of interval-based dual-chamber supraventricular tachycardia (SVT)–VT discrimination algorithms. Thus, atrial sensing in dual-chamber implantable cardioverter-defibrillators (ICDs) must...

متن کامل

Intermittent atrial undersensing in single-lead VDD pacemakers in patients with bradycardia-sensitive repolarization: a possible mechanism for ventricular arrhythmia.

Intermittent atrial undersensing in patients with single-lead VDD pacemakers is regarded as being of limited clinical significance. Nevertheless, in patients with bradycardia-mediated repolarization abnormalities, undersensing could result in RR-interval oscillations due to changes in pacemaker mode and this could act as a trigger for the initiation of torsades de pointes. We report our finding...

متن کامل

Paradoxical atrial undersensing by a dual chamber pacemaker during atrial fibrillation.

This report describes paradoxical atrial undersensing by a dual chamber pacemaker in a patient with paroxysmal atrial fibrillation. Atrial undersensing was present only when the device was programmed to a high sensitivity but sensing normalized when a lower sensitivity was programmed. This unusual response should be differentiated from the recently documented lock-in behavior of pacemakers deli...

متن کامل

Delayed AICD therapy and cardiac arrest resulting from undersensing of ventricular fibrillation in a subject with hypertrophic cardiomyopathy-A case report.

Defibrillation testing is no longer routinely performed after automatic implantable cardioverter-defibrillator (AICD) implantation. However, certain subjects undergoing AICD implantation may be at higher risk of undersensing of ventricular arrhythmias resulting in potentially fatal outcomes. We present the case of a 30-year-old woman with hypertrophic cardiomyopathy (HCM; 'asymmetric septal hyp...

متن کامل