Reproducibility of the NEI Scheimpflug Cataract Imaging System.
نویسندگان
چکیده
PURPOSE The NEI Scheimpflug Cataract Imaging System was developed to allow for easy, accurate and reproducible image analysis of nuclear cataracts. This study was undertaken to determine the reproducibility of densitometric measurements of the lens nucleus using this modified system. METHODS Replicate Zeiss Scheimpflug images of the lenses in 143 eyes were obtained by one photographer. Normal and cataractous lenses (without central cortical or anterior subcapsular opacities) were sampled. Images were stored after testing for adequacy using immediate exposure checking. Densitometry of the nuclear region was then performed for each image. The interval within which 99% of the differences between repeat measurements may be expected to lie was used as a measure of reproducibility (99% range). RESULTS A 99% range of +/- 0.023 optical density units (odu) was obtained for nuclear densities < 0.30 odu (125 eyes). For lenses with nuclear densities > or = 0.30 odu (18 eyes), the 99% range was +/- 0.14 times the first measurement. CONCLUSION This study shows the excellent reproducibility of this Scheimpflug imaging system in the nuclear region and demonstrates its usefulness in studies on nuclear cataracts, particularly for natural history studies and clinical trials of anti-cataract drugs.
منابع مشابه
Study of nuclear cataract progression using the National Eye Institute Scheimpflug system.
AIMS A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examine...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملCentral corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.
PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, I...
متن کاملTilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.
PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...
متن کاملRepeatability and validity of lens densitometry measured with Scheimpflug imaging.
PURPOSE To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 35 7 شماره
صفحات -
تاریخ انتشار 1994