Detection of Magnetic Transitions by Means of Ferromagnetic Resonance and Microwave Absorption Techniques

نویسندگان

  • H. Montiel
  • G. Alvarez
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High - field ESR Studies of the Quantum Spin Dimer System Ba 3 Cr 2 O

Results of systematic high-frequency electron spin resonance (ESR) studies of Ba3Cr2O8, a weakly coupled S = 2 dimer system, in magnetic fields up to 25 T are reported. Two pairs of ESR gapped modes corresponding to transitions from a spin-singlet ground state to the first excited triplet states with gaps, AB = 563 GHz and CD = 399 GHz, are revealed below Hc1 = 12.5 T. The detection of the grou...

متن کامل

One-pot three-component synthesis of tetrahydrobenzo[b]pyrans in the presence of Ni0.5Cu0.5Fe2O4 magnetic nanoparticles under microwave irradiation in solvent-free conditions

Ni0.5Cu0.5Fe2O4 magnetic nanoparticles using Arabic gel (AG) as a reducing and stabilizing agent was prepared by the sol-method. The catalyst identification was performed using Fourier transform infrared spectroscopy (FT-IR), powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), and vibrating sample magnetometer (VSM). The magnetic anal...

متن کامل

Spatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy

The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...

متن کامل

6 On - chip detection of ferromagnetic resonance of a single submicron permalloy strip

We measured ferromagnetic resonance of a single submicron ferromagnetic strip, embedded in an on-chip microwave transmission line device. The method used is based on detection of the oscillating magnetic flux due to the magnetization dynamics, with an inductive pickup loop. The dependence of the resonance frequency on applied static magnetic field agrees very well with the Kittel formula, demon...

متن کامل

Experimental evidence of left handed transmission through arrays of ferromagnetic microwires

Experimental evidence of left-handed transmission is demonstrated through an array of ferromagnetic microwires. We used amorphous magnetic microwires to take advantage of both electric and magnetic responses locally generating a double negative medium at microwave frequencies, where the ferromagnetic resonance effects take place. The dilution of the responses of the ferromagnetic material provi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017