PURPOSE: To evaluate the effect of various implant-level impression techniques on the accuracy of definitive casts for a multiple internal connection implant system with different implant angulations and subgingival depths. MATERIAL AND METHODS: Six tapered Screw-Vent implants were placed in a reference model with different angles (0, 15, and 30 degrees) and subgingival positions (0, 1, and 3 mm). Twenty medium-consistency polyether impressions of this model were made with 4 techniques (n = 5 per group): (1) indirect technique, (2) unsplinted direct technique, (3) acrylic resin-splinted direct technique, and (4) metal-splinted direct technique. Impressions were poured with type IV dental stone. The interimplant distances were measured for casts using a coordinate measuring machine and the deviations compared with the reference model were calculated. Data were analyzed using intraclass correlation coefficient, ANOVA and Bonferroni test (� = 0.05). RESULTS: Four impression procedures showed significant differences (P = 0.0001). Only group 4 casts showed no significant differences in comparison with the reference model (P = 0.666) (ANOVA repeated measures). CONCLUSIONS: The impression procedure affected the accuracy of definitive casts. The metal-splinted direct technique produced the most accurate casts, followed by acrylic resin-splinted direct, indirect, and unsplinted direct techniques. DOI: https://doi.org/10.1097/ID.0b013e3182920dc5 Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: https://doi.org/10.5167/uzh-89892 Accepted Version Originally published at: Martínez-Rus, Francisco; García, Carmen; Santamaría, Andrea; Özcan, Mutlu; Pradíes, Guillermo (2013). Accuracy of definitive casts using 4 implant-level impression techniques in a scenario of multiimplant system with different implant angulations and subgingival alignment levels. Implant Dentistry, 22(3):268-276. DOI: https://doi.org/10.1097/ID.0b013e3182920dc5
منابع مشابه
Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis.
PURPOSE To assess the three-dimensional (3D) accuracy and clinical acceptability of implant definitive casts fabricated using a digital impression approach and to compare the results with those of a conventional impression method in a partially edentulous condition. MATERIALS AND METHODS A mandibular reference model was fabricated with implants in the first premolar and molar positions to sim...
متن کاملAccuracy of two impression techniques with angulated implants.
STATEMENT OF PROBLEM Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. PURPOSE The purpose of this study was to determine the effect the combined intera...
متن کاملAccuracy of a proposed implant impression technique using abutments and metal framework
PURPOSE This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cementon crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS Thre...
متن کاملCast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
BACKGROUND Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. METHODS Three Osseolink implants were placed in three reference mo...
متن کاملEffect of different impression materials and techniques on the dimensional accuracy of implant definitive casts
BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxilla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -