Comparison of pentastarch and Hartmann's solution for volume preloading in spinal anaesthesia for elective caesarean section.

نویسندگان

  • G W French
  • J B White
  • S J Howell
  • M Popat
چکیده

We studied 160 patients undergoing elective Caesarean section under spinal anaesthesia who received a preloading volume of 15 ml kg-1 of 10% pentastarch in 0.9% saline, or Hartmann's solution, in a prospective, randomized, double-blind study. We compared the incidence of spinal-induced hypotension in each group. Hypotension was defined as a decrease in systolic arterial pressure to less than 70% of baseline values or < or = 90 mm Hg, whichever was the greater. The groups were comparable in physical characteristics and there was no serious morbidity. Fetal outcome was similar in both groups. Significantly more patients in the Hartmann's group (n = 38, 47.5%) developed hypotension than in the pentastarch group (n = 10, 12.5%) (P < 0.0001). Linear regression analysis showed that the only significant variable was type of fluid used. Blood glucose concentrations were not related to the presence of hypotension. We conclude that starches may be suitable for preloading in Caesarean section under spinal anaesthesia and provide an alternative to the aggressive use of vasoconstrictors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume preloading is not essential to prevent spinal-induced hypotension at caesarean section.

We have compared the protective effect of 1000 ml preload with 200 ml preload of crystalloid solution, administered during the 10 min before spinal anaesthesia was induced, in 60 healthy women with no fetal compromise undergoing elective Caesarean section. The spinal anaesthetic was managed identically in both groups by an anaesthetist who was unaware of the volume of fluid administered. A prop...

متن کامل

Ventilatory management of severe acute respiratory failure for Y2K.

condition of mother and infant at cesarean section. Anesth Analg 1969; 48:986–93 8. Clark RB, Thompson DS, Thompson CH: Prevention of spinal hypotension associated with cesarean section. ANESTHESIOLOGY 1976; 45:670–4 9. Russell IF: Effect of posture during the induction of subarachnoid analgesia for caesarean section. Right v left lateral. Br J Anaesth 1987; 59:342–6 10. Norris MC: Hypotension ...

متن کامل

مقایسه اثر هیدروکسی اتیل استارچ با کریستالوئیدها بر تغییرات همودینامیک

Aims and Background: Although controversial, many studies have shown effectiveness of colloid loading as a substitute for crystalloids on reducing the incidence of hypotension in spinal anesthesia. This study was conducted to compare the effects of three intravenous fluid regimens on hemodynamic changes following spinal anesthesia in cesarean section. The regimens included 6% Hydroxy ethyl star...

متن کامل

Fetal blood flow during intrathecal anaesthesia for elective caesarean section.

Fetal aortic and umbilical blood flows were studied in 15 mothers before and during spinal (intrathecal) anaesthesia for elective Caesarean section, using a method combining real-time ultrasonography and a pulsed Doppler technique. Spinal anaesthesia with 0.5% bupivacaine hydrochloride 2.5 ml in 8% glucose monohydrate solution was administered after preloading with 2 litre of lactated Ringer's ...

متن کامل

Effect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section.

We have studied the effects of crystalloid 1 litre (lactated Ringer's) or colloid 0.5 litre (hydroxyethyl starch) preloading in 26 healthy parturients undergoing elective Caesarean section under spinal anaesthesia. Maternal placental uterine artery circulation was measured using a pulsed colour Doppler technique with simultaneous measurement of maternal haemodynamics. A high incidence of matern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 83 3  شماره 

صفحات  -